Flux RSS

— Sources secondaires
133articles RSS
Reinitialiser
China-Linked Red Menshen Uses Stealthy BPFDoor Implants to Spy via Telecom Networks
Gouvernance & RégulationThe Hacker Newsavant-hier

A long-term and ongoing campaign attributed to a China-nexus threat actor has embedded itself in telecom networks to conduct espionage against government networks. The strategic positioning activity, which involves implanting and maintaining stealthy access mechanisms within critical environments, has been attributed to Red Menshen, a threat cluster that's also tracked as Earth Bluecrow,

UK sanctions Xinbi marketplace linked to Asian scam centers
Fuites de donnéesBleepingComputeravant-hier

The United Kingdom's Foreign, Commonwealth and Development Office (FCDO) has sanctioned Xinbi, a Chinese-language cryptocurrency-based online marketplace that sells stolen data and satellite internet equipment to scam networks in Southeast Asia. [...]

WhatsApp rolls out more AI features, iOS multi-account support
GénéralBleepingComputeravant-hier

WhatsApp is rolling out multiple features designed to make the app easier to use, including AI-powered message replies and photo retouching, support for two accounts on iOS, and chat history transfer between iOS and Android devices. [...]

[Webinar] Stop Guessing. Learn to Validate Your Defenses Against Real Attacks
Gouvernance & RégulationThe Hacker Newsavant-hier

Most teams have security tools in place. Alerts are firing, dashboards look clean, threat intel is flowing in. On the surface, everything feels under control. But one question usually stays unanswered: Would your defenses actually stop a real attack? That’s where things get shaky. A control exists, so it’s assumed to work. A detection rule is active, so it’s expected to catch something. But very

Claude Extension Flaw Enabled Zero-Click XSS Prompt Injection via Any Website
Gouvernance & RégulationThe Hacker Newsavant-hier

Cybersecurity researchers have disclosed a vulnerability in Anthropic's Claude Google Chrome Extension that could have been exploited to trigger malicious prompts simply by visiting a web page. The flaw "allowed any website to silently inject prompts into that assistant as if the user wrote them," Koi Security researcher Oren Yomtov said in a report shared with The Hacker News. "No clicks, no

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesavant-hier

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33634 Aqua Security Trivy Embedded Malicious Code Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

PTC Windchill Product Lifecycle Management
Gouvernance & RégulationCISA Advisoriesavant-hier

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. The following versions of PTC Windchill Product Lifecycle Management are affected: Windchill PDMLink 11.0_M030 (CVE-2026-4681) Windchill PDMLink 11.1_M020 (CVE-2026-4681) Windchill PDMLink 11.2.1.0 (CVE-2026-4681) Windchill PDMLink 12.0.2.0 (CVE-2026-4681) Windchill PDMLink 12.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.0.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.0.0 (CVE-2026-4681) Windchill PDMLink 13.1.1.0 (CVE-2026-4681) Windchill PDMLink 13.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.3.0 (CVE-2026-4681) FlexPLM 11.0_M030 (CVE-2026-4681) FlexPLM 11.1_M020 (CVE-2026-4681) FlexPLM 11.2.1.0 (CVE-2026-4681) FlexPLM 12.0.0.0 (CVE-2026-4681) FlexPLM 12.0.2.0 (CVE-2026-4681) FlexPLM 12.0.3.0 (CVE-2026-4681) FlexPLM 12.1.2.0 (CVE-2026-4681) FlexPLM 12.1.3.0 (CVE-2026-4681) FlexPLM 13.0.2.0 (CVE-2026-4681) FlexPLM 13.0.3.0 (CVE-2026-4681) CVSS Vendor Equipment Vulnerabilities v3 10 PTC PTC Windchill Product Lifecycle Management Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-4681 A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0. View CVE Details Affected Products PTC Windchill Product Lifecycle Management Vendor: PTC Product Version: PTC Windchill PDMLink: 11.0_M030, PTC Windchill PDMLink: 11.1_M020, PTC Windchill PDMLink: 11.2.1.0, PTC Windchill PDMLink: 12.0.2.0, PTC Windchill PDMLink: 12.1.2.0, PTC Windchill PDMLink: 13.0.2.0, PTC Windchill PDMLink: 13.1.0.0, PTC Windchill PDMLink: 13.1.1.0, PTC Windchill PDMLink: 13.1.2.0, PTC Windchill PDMLink: 13.1.3.0, PTC FlexPLM: 11.0_M030, PTC FlexPLM: 11.1_M020, PTC FlexPLM: 11.2.1.0, PTC FlexPLM: 12.0.0.0, PTC FlexPLM: 12.0.2.0, PTC FlexPLM: 12.0.3.0, PTC FlexPLM: 12.1.2.0, PTC FlexPLM: 12.1.3.0, PTC FlexPLM: 13.0.2.0, PTC FlexPLM: 13.0.3.0 Product Status: known_affected Remediations Mitigation PTC is aware of the issue and is actively developing a fix. In the meantime, PTC recommends applying the recommended workaround. Until official patches are available, customers must take urgent steps to safeguard their environments. Specifically: Protect any publicly accessible Windchill systems Vendor fix While publicly accessible Windchill and FlexPLM systems are at higher risk and require immediate attention, PTC strongly recommends applying the mitigation steps to all deployments, regardless of Internet exposure Vendor fix Apply the same precautions to FlexPLM deployments Vendor fix The following Apache and IIS HTTP Server configuration update should be IMMEDIATELY applied to every Windchill or FlexPLM system: Customers using Apache HTTP Server should only follow "Apache HTTP Server Configuration – Workaround Steps" section steps Mitigation Customers using Microsoft IIS should only follow "IIS Configuration - Workaround Steps" section steps Mitigation Please explicitly note that the same mitigation steps must also be applied on File Server / Replica Server configurations where applicable Mitigation For Windchill releases prior to 11.0 M030, workarounds may need to be altered to apply to unsupported previous releases Mitigation For Apache HTTP Server and IIS configuration workaround steps, please refer to the official advisory at:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Mitigation If immediate remediation is not feasible, additional guidance and remediation options are available:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments An anonymous source reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of PTC's CS466318 Legal Notice and Terms of Use

OpenCode Systems OC Messaging and USSD Gateway
Gouvernance & RégulationCISA Advisoriesavant-hier

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter. The following versions of OpenCode Systems OC Messaging and USSD Gateway are affected: OC Messaging 6.32.2 (CVE-2025-70614) USSD Gateway 6.32.2 (CVE-2025-70614) CVSS Vendor Equipment Vulnerabilities v3 8.1 OpenCode Systems OpenCode Systems OC Messaging and USSD Gateway Improper Access Control Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: Bulgaria Vulnerabilities Expand All + CVE-2025-70614 OpenCode Systems Custom Messaging Gateway 6.32.2 contains a web access vulnerability allowing one authenticated user to gain access to another authenticated user's messages via a crafted identifier parameter. View CVE Details Affected Products OpenCode Systems OC Messaging and USSD Gateway Vendor: OpenCode Systems Product Version: OpenCode Systems OC Messaging: 6.32.2, OpenCode Systems USSD Gateway: 6.32.2 Product Status: known_affected Remediations Mitigation The vulnerability was identified by OpenCode Systems on January 5, 2026 and remediated on January 6, 2026 with the release of version 6.33.11. Mitigation For more information, contact OpenCode: https://opencode.com/about/contact-us https://opencode.com/about/contact-us Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N Acknowledgments Hussein Amer reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Publication Legal Notice and Terms of Use

WAGO GmbH & Co. KG Industrial Managed Switches
Gouvernance & RégulationCISA Advisoriesavant-hier

View CSAF Summary An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. The following versions of WAGO GmbH & Co. KG Industrial Managed Switches are affected: WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware version V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware version V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S1 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) CVSS Vendor Equipment Vulnerabilities v3 10 WAGO WAGO GmbH & Co. KG Industrial Managed Switches Hidden Functionality Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-3587 An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. View CVE Details Affected Products WAGO GmbH & Co. KG Industrial Managed Switches Vendor: WAGO Product Version: WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware versions prior to V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware versions prior to V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware versions prior to V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware versions prior to V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware version V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware version V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware version V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-001, WAGO WAGO Firmware version V1.2.1.S1: WAGO_Hardware_852-1813/010-001 Product Status: known_affected Remediations Mitigation WAGO has identified the following specific workarounds and mitigations users can apply to reduce risk: Product Group: WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1813/010-001, WAGO Firmware installed on WAGO Hardware 852-1813/010-001): Please update your devices to the specified fixed Firmware version. Mitigation Lean Managed Switch 852-1812, Lean Managed Switch 852-1813, Lean Managed Switch 852-1813/000-001, Lean Managed Switch 852-1816, Lean Managed Switch 852-1812/010-000, Lean Managed Switch 852-1813/010-000, Lean Managed Switch 852-1816/010-000, Lean Managed Switch 852-1813/010-001: To eliminate the attack vector deactivate ssh and telnet on the device. Mitigation Industrial Managed Switch 852-303, Industrial Managed Switch 852-1305, Industrial Managed Switch 852-1305/000-001, Industrial Managed Switch 852-1505/000-001, Industrial Managed Switch 852-1505, Industrial Managed Switch 852-602, Industrial Managed Switch 852-603, Industrial Managed Switch 852-1605: To reduce the attack vector deactivate ssh and telnet on the devices. This ensures that the CLI is only accessible locally via RS232. Mitigation The following product versions have been fixed: Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.3.S1 installed on Lean Managed Switch 852-1813/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.8.S1 installed on Industrial Managed Switch 852-303 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1505/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.1.9.S1 installed on Industrial Managed Switch 852-1505 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-602 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-603 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.5.S1 installed on Industrial Managed Switch 852-1605 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-001 are fixed versions for CVE-2026-3587 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://www.wago.com/de-en/automation-technology/psirt Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://certvde.com/en/advisories/VDE-2026-020 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json Relevant CWE: CWE-912 Hidden Functionality Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments CERT@VDE coordination reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of WAGO GmbH & Co. KG VDE-2026-020 Legal Notice and Terms of Use

Masters of Imitation: How Hackers and Art Forgers Perfect the Art of Deception
GénéralThe Hacker Newsavant-hier

Unmasking impostors is something the art world has faced for decades, and there are valuable lessons from the works of Elmyr de Hory that can apply to the world of defensive cybersecurity. During the 1960s, de Hory gained infamy as a premier forger, passing off counterfeit masterworks of Picasso, Matisse, and Renoir to unsuspecting collectors and renowned museums. Over the next several decades,

Suspected RedLine infostealer malware admin extradited to US
Malware & RansomwareBleepingComputeravant-hier

An Armenian suspect was extradited to the United States to face criminal charges for allegedly helping manage RedLine, one of the most prolific infostealer malware operations in recent years. [...]

ThreatsDay Bulletin: PQC Push, AI Vuln Hunting, Pirated Traps, Phishing Kits & 20 More Stories
Gouvernance & RégulationThe Hacker Newsavant-hier

Some weeks in security feel loud. This one feels sneaky. Less big dramatic fireworks, more of that slow creeping sense that too many people are getting way too comfortable abusing things they probably shouldn’t even be touching. There’s a little bit of everything in this one, too. Weird delivery tricks, old problems coming back in slightly worse forms, shady infrastructure doing

Coruna iOS Kit Reuses 2023 Triangulation Exploit Code in Recent Mass Attacks
Gouvernance & RégulationThe Hacker Newsavant-hier

The kernel exploit for two security vulnerabilities used in the recently uncovered Apple iOS exploit kit known as Coruna is an updated version of the same exploit that was used in the Operation Triangulation campaign back in 2023, according to new findings from Kaspersky. "When Coruna was first reported, the public evidence wasn't sufficient to link its code to Triangulation — shared

WebRTC Skimmer Bypasses CSP to Steal Payment Data from E-Commerce Sites
Gouvernance & RégulationThe Hacker Newsavant-hier

Cybersecurity researchers have discovered a new payment skimmer that uses WebRTC data channels as a means to receive payloads and exfiltrate data, effectively bypassing security controls. "Instead of the usual HTTP requests or image beacons, this malware uses WebRTC data channels to load its payload and exfiltrate stolen payment data," Sansec said in a report published this week. The attack,