View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send a specially crafted file, and when parsed, could result in a denial-of-service condition. The following versions of Grassroots DICOM (GDCM) are affected: Grassroots DICOM (GDCM) 3.2.2 (CVE-2026-3650) CVSS Vendor Equipment Vulnerabilities v3 7.5 Grassroots Grassroots DICOM (GDCM) Missing Release of Memory after Effective Lifetime Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3650 A memory leak exists in the Grassroots DICOM library (GDCM). The bug occurs when parsing malformed DICOM files with non-standard VR types in file meta information. The vulnerability leads to vast memory allocations and resource depletion, triggering a denial-of-service condition. A maliciously crafted file can fill the heap in a single read operation without properly releasing it. View CVE Details Affected Products Grassroots DICOM (GDCM) Vendor: Grassroots Product Version: Grassroots Grassroots DICOM (GDCM): 3.2.2 Product Status: known_affected Remediations Mitigation The maintainer of Grassroots DICOM (GDCM) has not responded to requests to work with CISA to mitigate this vulnerability. For update information refer to the software page on SourceForge. Mitigation https://sourceforge.net/projects/gdcm/. https://sourceforge.net/projects/gdcm/ Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Volodymyr Bihunenko, Mykyta Mudryi, and Markiian Chaklosh of ARIMLABS reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication. Legal Notice and Terms of Use
Flux RSS
— Sources secondairesJapan’s election last month and the rise of the country’s newest and most innovative political party, Team Mirai, illustrates the viability of a different way to do politics. In this model, technology is used to make democratic processes stronger, instead of undermining them. It is harnessed to root out corruption, instead of serving as a cash cow for campaign donations. Imagine an election where every voter has the opportunity to opine directly to politicians on precisely the issues they care about. They’re not expected to spend hours becoming policy experts. Instead, an AI Interviewer walks them through the subject, answering their questions, interrogating their experience, even challenging their thinking. Voters get immediate feedback on how their individual point of view matches—or doesn’t—a party’s platform, and they can see whether and how the party adopts their feedback. This isn’t like an opinion poll that politicians use for calculating short-term electoral tactics. It’s a deliberative reasoning process that scales, engaging voters in defining policy and helping candidates to listen deeply to their constituents. This is happening today in Japan. Constituents have spent about eight thousand hours engaging with Mirai’s AI Interviewer since 2025. The party’s gamified volunteer mobilization app, Action Board, captured about 100,000 organizer actions per day in the runup to last week’s election. It’s how Team Mirai, which translates to ‘The Future Party,’ does politics. Its founder, Takahiro Anno, first ran for local office in 2024 as a 33 year old software engineer standing for Governor of Tokyo. He came in fifth out of 56 candidates, winning more than 150,000 votes as an unaffiliated political outsider. He won attention by taking a distinctive stance on the role of technology in democracy and using AI aggressively in voter engagement. Last year, Anno ran again, this time for the Upper Chamber of the national legislature—the Diet—and won. Now the head of a new national party, Anno found himself with a platform for making his vision of a new way of doing politics a reality. In this recent House of Representatives election, Team Mirai shot up to win nearly four million votes. In the lower chamber’s proportional representation system, that was good enough for eleven total seats—the party’s first ever representation in the Japanese House—and nearly three times what it achieved in last year’s Upper Chamber election. Anno’s party stood for election without aligning itself on the traditional axes of left and right. Instead, Team Mirai, heavily associated with young, urban voters, sought to unite across the ideological spectrum by taking a radical position on a different axis: the status quo and the future. Anno told us that Team Mirai believes it can triple its representation in the Diet after the next elections in each chamber, an ostentatious goal that seems achievable given their rapid rise over the past year. In the American context, the idea of a small party unifying voters across left and right sounds like a pipe dream. But there is evidence it worked in Japan. Team Mirai won an impressive 11% of proportional representation votes from unaffiliated voters, nearly twice the share of the larger electorate. The centerpiece of the party’s policy platform is not about the traditional hot button issues, it’s about democracy itself, and how it can be enhanced by embracing a futuristic vision of digital democracy. Anno told us how his party arrived at its manifesto for this month’s elections, and why it looked different from other parties’ in important ways. Team Mirai collected more than 38,000 online questions and more than 6,000 discrete policy suggestions from voters using its AI Policy app, which is advertised as a ‘manifesto that speaks for itself.’ After factoring in all this feedback, Team Mirai maintained a contrarian position on the biggest issue of the election: the sales tax and affordability. Rather than running on a reduction of the national sales tax like the major parties, Team Mirai reviewed dozens of suggestions from the public and ultimately proposed to keep that tax level while providing support to families through a child tax credit and lowering the required contribution for social insurance. Anno described this as another future-facing strategy: less price relief in the short term, but sustained funding for essential programs. Anno has always intended to build a different kind of party. After receiving roughly $1 million in public funding apportioned to Team Mirai based on its single seat in the Upper Chamber last year, Anno began hiring engineers to enhance his software tools for digital democracy. Anno described Team Mirai to us as a ‘utility party;’ basic infrastructure for Japanese democracy that serves the broader polity rather than one faction. Their Gikai (‘assembly’) app illustrates the point. It provides a portal for constituents to research bills, using AI to generate summaries, to describe their impacts, to surfacing media reporting on the issue, and to answer users’ questions. Like all their software, it’s open source and free for anyone, in any party, to use. After last week’s victory, Team Mirai now has about $5 million in public funding and ambitions to grow the influence of their digital democracy platform. Anno told us Team Mirai has secured an agreement with the LDP, Japan’s dominant ruling party, to begin using Team Mirai’s Gikai and corruption-fighting Mirumae financial transparency tool. AI is the issue driving the most societal and economic change we will encounter in our lifetime, yet US political parties are largely silent. But AI and Big Tech companies and their owners are ramping up their political spending to influence the parties. To the extent that AI has shown up in our politics, it seems to be limited to the question of where to site the next generation of data centers and how to channel populist backlash to big tech. Those are causes worthy of political organizing, but very few US politicians are leveraging the technology for public listening or other pro-democratic purposes. With the midterms still nine months away and with innovators like Team Mirai making products in the open for anyone to use, there is still plenty of time for an American politician to demonstrate what a new politics could look like. This essay was written with Nathan E. Sanders, and originally appeared in Tech Policy Press.
Press release 26/07
It’s an impressive feat, over a decade after the box was released: Since reset glitching wasn’t possible, Gaasedelen thought some voltage glitching could do the trick. So, instead of tinkering with the system rest pin(s) the hacker targeted the momentary collapse of the CPU voltage rail. This was quite a feat, as Gaasedelen couldn’t ‘see’ into the Xbox One, so had to develop new hardware introspection tools. Eventually, the Bliss exploit was formulated, where two precise voltage glitches were made to land in succession. One skipped the loop where the ARM Cortex memory protection was setup. Then the Memcpy operation was targeted during the header read, allowing him to jump to the attacker-controlled data. As a hardware attack against the boot ROM in silicon, Gaasedelen says the attack in unpatchable. Thus it is a complete compromise of the console allowing for loading unsigned code at every level, including the Hypervisor and OS. Moreover, Bliss allows access to the security processor so games, firmware, and so on can be decrypted.
The population needs better conservation. As usual, you can also use this squid post to talk about the security stories in the news that I haven’t covered. Blog moderation policy.
CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-31277 Apple Multiple Products Buffer Overflow Vulnerability CVE-2025-32432 Craft CMS Code Injection Vulnerability CVE-2025-43510 Apple Multiple Products Improper Locking Vulnerability CVE-2025-43520 Apple Multiple Products Classic Buffer Overflow Vulnerability CVE-2025-54068 Laravel Livewire Code Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
CISA and the Federal Bureau of Investigation released a Public Service Announcement (PSA) warning about ongoing phishing campaigns by cyber actors associated with the Russian Intelligence Services targeting commercial messaging applications (CMAs). These campaigns aim to bypass encryption to compromise to individual user accounts with targets including current and former U.S. government officials, military personnel, political figures, and journalists. Evidence shows that cyber actors have been able to compromise individual CMA accounts, but not encryption of the applications themselves. The actors’ global campaigns have resulted in unauthorized access to thousands of individual CMA accounts to view the victims’ messages and contact lists, send messages, and conduct additional phishing against other CMA accounts. CISA and FBI urge CMA users to review the PSA, follow recommended cybersecurity practices, and remain vigilant for suspicious activity.
404 Media has a story about Proton Mail giving subscriber data to the Swiss government, who passed the information to the FBI. It’s metadata—payment information related to a particular account—but still important knowledge. This sort of thing happens, even to privacy-centric companies like Proton Mail.
Situation as at 31 December 2025
(first publication: 30 October 2024)
Situation as at 31 December 2025
Situation as at 31 December 2025
View CSAF Summary Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser. The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon Controllers M258 all firmware versions Modicon_Controllers_M258 Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058 CVSS Vendor Equipment Vulnerabilities v3 5.4 Schneider Electric Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. View CVE Details Affected Products Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000003059/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/us/en/download/document/EIO0000003089/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N Acknowledgments Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-25192 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-31904 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27649 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-28204 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine, Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of IGL-Technologies eParking.fi are affected: eParking.fi vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 IGL-Technologies IGL-Technologies eParking.fi Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-29796 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-31903 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-32663 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-31926 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products. The following versions of Mitsubishi Electric CNC Series are affected: M800VW (BND-2051W000) <=BB M800VS (BND-2052W000) <=BB M80V (BND-2053W000) <=BB M80VW (BND-2054W000) <=BB M800W (BND-2005W000) <=FM M800S (BND-2006W000) <=FM M80 (BND-2007W000) <=FM M80W (BND-2008W000) <=FM E80 (BND-2009W000) <=FM C80 (BND-2036W000) vers:all/* M750VW (BND-1015W002) vers:all/* M730VW (BND-1015W000) vers:all/* M720VW (BND-1015W000) vers:all/* M750VS (BND-1012W002) vers:all/* M730VS (BND-1012W000-**) vers:all/* M720VS (BND-1012W000) vers:all/* M70V (BND-1018W000) vers:all/* E70 (BND-1022W000) vers:all/* NC Trainer2 (BND-1802W000) vers:all/* NC Trainer2 plus (BND-1803W000) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.9 Mitsubishi Electric Mitsubishi Electric CNC Series Improper Validation of Specified Index, Position, or Offset in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-2399 Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683. View CVE Details Affected Products Mitsubishi Electric CNC Series Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric M800VW (BND-2051W000): <=BB, Mitsubishi Electric M800VS (BND-2052W000): <=BB, Mitsubishi Electric M80V (BND-2053W000): <=BB, Mitsubishi Electric M80VW (BND-2054W000): <=BB, Mitsubishi Electric M800W (BND-2005W000): <=FM, Mitsubishi Electric M800S (BND-2006W000): <=FM, Mitsubishi Electric M80 (BND-2007W000): <=FM, Mitsubishi Electric M80W (BND-2008W000): <=FM, Mitsubishi Electric E80 (BND-2009W000): <=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): vers:all/*, Mitsubishi Electric M730VW (BND-1015W000): vers:all/*, Mitsubishi Electric M720VW (BND-1015W000): vers:all/*, Mitsubishi Electric M750VS (BND-1012W002): vers:all/*, Mitsubishi Electric M730VS (BND-1012W000): vers:all/*, Mitsubishi Electric M720VS (BND-1012W000): vers:all/*, Mitsubishi Electric M70V (BND-1018W000): vers:all/*, Mitsubishi Electric E70 (BND-1022W000): vers:all/*, Mitsubishi Electric NC Trainer2 (BND-1802W000): vers:all/*, Mitsubishi Electric NC Trainer2 plus (BND-1803W000): vers:all/* Product Status: known_affected Remediations Vendor fix Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW(BND-2051W000), M800VS(BND-2052W000), M80V(BND-2053W000), and M80VW(BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Vendor fix Please apply the fixed version (FN or later) for Mitsubishi Electric M800W(BND-2005W000), M800S(BND-2006W000), M80(BND-2007W000), M80W(BND-2008W000), and E80(BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product: M800V/M80V Series Instruction Manual "16. Appendix 3 IP Address Filter Setting Function", M800/M80/E80 Series Instruction Manual "15. Appendix 2 IP Address Filter Setting Function" Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For more information, see Mitsubishi Electric 2025-022. https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-022_en.pdf Relevant CWE: CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Mitsubishi Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of CISA V20250121-001#02 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact CISA directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial CISA Republication of Mitsubishi Electric security advisory 2025-022 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to read, intercept, or modify communications. The following versions of Automated Logic WebCTRL Premium Server are affected: WebCTRL Premium Server CVSS Vendor Equipment Vulnerabilities v3 9.1 Automated Logic Automated Logic WebCTRL Premium Server Multiple Binds to the Same Port, Authentication Bypass by Spoofing, Cleartext Transmission of Sensitive Information Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-25086 Under certain conditions, an attacker could bind to the same port used by WebCTRL. This could allow the attacker to craft and send malicious packets and impersonate the WebCTRL service without requiring code injection into the WebCTRL software. View CVE Details Affected Products Automated Logic WebCTRL Premium Server Vendor: Automated Logic Product Version: Automated Logic WebCTRL Premium Server: