CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20131 Cisco Secure Firewall Management Center (FMC) Software and Cisco Security Cloud Control (SCC) Firewall Management Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Flux RSS
— Sources secondairesView CSAF Summary Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser. The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon Controllers M258 all firmware versions Modicon_Controllers_M258 Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058 CVSS Vendor Equipment Vulnerabilities v3 5.4 Schneider Electric Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. View CVE Details Affected Products Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000003059/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/us/en/download/document/EIO0000003089/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N Acknowledgments Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-25192 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-31904 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27649 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-28204 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine, Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Publication Legal Notice and Terms of Use
The European Union – the media freedom hub marsrgi Thu, 03/19/2026 - 08:58 Opening: 16 April 2026 Closing: 28 May 2026 The overall goal of this preparatory action is to continue the activities of the ongoing Free Media Hub EAST project, i.e. to sustain and improve existing financial and other kinds of support to exiled independent media from Russia, Belarus, as well as media from Ukraine that has relocated in the EU, and to foster the coordination and consolidation of a pan-European platform or network of media hubs to promote the preservation of a pluralistic media environment. GettyImages © Mihajlo Maricic Main link https://ec.europa.eu/info/funding-tenders/opportunities/portal/screen/opportuni… Related topics Media and democracy Media freedom and pluralism International relations Funding for Digital Actions to Support Ukraine Democracy in the digital age {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.1 To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions. To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft’s newly released best practices for securing Microsoft Intune; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software: Use principles of least privilege when designing administrative roles. Leverage Microsoft Intune’s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations—permissions include what actions the role can take, and what users and devices it can apply that action to. Enforce phishing-resistant multi-factor authentication (MFA) and privileged access hygiene. Use Microsoft Entra ID capabilities (including Conditional Access, MFA, risk signals, and privileged access controls) to block unauthorized access to privileged actions in Microsoft Intune. Configure access policies to require Multi Admin Approval in Microsoft Intune. Set up policies that require a second administrative account’s approval to allow changes to sensitive or high-impact actions (such as device wiping), applications, scripts, RBAC, configurations, etc. Additionally, CISA recommends reviewing the following resources to strengthen defenses against similar malicious cyber activity: Microsoft resources: For recommendations on securing Microsoft Intune, see Best practices for securing Microsoft Intune. For guidance on implementing Multi Admin Approval in Microsoft Intune, see Use Access policies to implement Multi Admin Approval. For recommendations on configuring Microsoft Intune using zero trust principles, see Configure Microsoft Intune for increased security. For guidance on implementing Microsoft Intune RBAC policies, see Role-based access control (RBAC) with Microsoft Intune. For guidance on deploying Privileged Identity Management (PIM) across Microsoft Intune, Entra ID, and other Microsoft software, see Plan a Privileged Identity Management deployment. CISA resources: For guidance on implementing phishing-resistant multifactor authentication (MFA), see Implementing Phishing-Resistant MFA. Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements Microsoft and Stryker contributed to this alert. Notes 1 For updates from Stryker on the incident, see “Customer Updates: Stryker Network Disruption,” Stryker, last modified March 15, 2026, https://www.stryker.com/us/en/about/news/2026/a-message-to-our-customers-03-2026.html.
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-66376 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20963 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
CEF-Digital Info Session: 2026 Calls Anonymous (not verified) Wed, 03/18/2026 - 10:35 26 March 2026 Online Learn more about the calls "Equipment for smart European cable systems" (CEF-DIG-2026-SMART-CABLES) and "Backbone connectivity for Digital Global Gateways" (CEF-DIG-2026-GATEWAYS). GettyImages © Dragon Claws Main link https://hadea.ec.europa.eu/events/cef-digital-info-session-2026-calls-2026-03-2… Related topics Connecting Europe Facility Funding for Digital Related content Press release 17 March 2026 Commission makes available €200 million for submarine cable and digital infrastructure projects The European Commission has opened two new Connecting Europe Facility (CEF) calls worth €200 million for projects in high-capacity networks, including submarine cables. {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens has released a new version for SICAM SIAPP SDK and recommends to update to the latest version. The following versions of Siemens SICAM SIAPP SDK are affected: SICAM SIAPP SDK vers:intdot/<2.1.7 CVSS Vendor Equipment Vulnerabilities v3 7.4 Siemens Siemens SICAM SIAPP SDK Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25569 An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25570 The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25571 The SICAM SIAPP SDK client component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25572 The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25573 The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25605 The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. Maxime Rossi Bellom of Secmate reported these vulnerabilities to Siemens. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-903736 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-17 2 Initial CISA Republication of Siemens ProductCERT SSA-903736 advisory Legal Notice and Terms of Use
View CSAF Summary 3. TECHNICAL DETAILS The following versions of CODESYS in Festo Automation Suite are affected: FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0) vers:all/* FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10) vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.8 FESTO, CODESYS CODESYS in Festo Automation Suite Direct Request ('Forced Browsing'), Untrusted Search Path, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Recursion, Improper Access Control, Use of Insufficiently Random Values, Improper Restriction of Communication Channel to Intended Endpoints, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), NULL Pointer Dereference, Stack-based Buffer Overflow, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Incorrect Permission Assignment for Critical Resource, Improper Handling of Exceptional Conditions, Exposure of Resource to Wrong Sphere, Allocation of Resources Without Limits or Throttling, Use of a Broken or Risky Cryptographic Algorithm, Out-of-bounds Write, Weak Password Recovery Mechanism for Forgotten Password, Improper Privilege Management, Use of Password Hash With Insufficient Computational Effort, Buffer Access with Incorrect Length Value, Improper Input Validation, Improper Verification of Cryptographic Signature, Inadequate Encryption Strength, Origin Validation Error, Missing Release of Memory after Effective Lifetime, Improper Resource Shutdown or Release, Deserialization of Untrusted Data, Path Equivalence: '//multiple/leading/slash', Insufficient Verification of Data Authenticity, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Out-of-bounds Read, Failure to Sanitize Special Elements into a Different Plane (Special Element Injection), Use of Out-of-range Pointer Offset, Improper Neutralization of Script in Attributes of IMG Tags in a Web Page, Files or Directories Accessible to External Parties, Untrusted Pointer Dereference, Path Traversal: '....' (Multiple Dot), ASP.NET Misconfiguration: Missing Custom Error Page, Uncontrolled Resource Consumption, Unprotected Transport of Credentials, Initialization of a Resource with an Insecure Default, Heap-based Buffer Overflow, Unexpected Sign Extension, Buffer Over-read, Uncontrolled Search Path Element, Improper Verification of Source of a Communication Channel, Improper Restriction of Excessive Authentication Attempts, Use After Free, ASP.NET Misconfiguration: Password in Configuration File, Improper Check for Unusual or Exceptional Conditions, Observable Discrepancy, Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2025-2595 An unauthenticated remote attacker can bypass the user management in CODESYS Visualization and read visualization template files or static elements by means of forced browsing. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-425 Direct Request ('Forced Browsing') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2010-5250 Untrusted search path vulnerability in the pthread_win32_process_attach_np function in pthreadGC2.dll in Pthreads-win32 2.8.0 allows local users to gain privileges via a Trojan horse quserex.dll file in the current working directory.NOTE: some of these details are obtained from third party information. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-426 Untrusted Search Path Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.8 HIGH CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2017-3735 While parsing an IPAddressFamily extension in an X.509 certificate, it is possible to do a one-byte overread. This would result in an incorrect text display of the certificate. This bug has been present since 2006 and is present in all versions of OpenSSL before 1.0.2m and 1.1.0g. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N CVE-2018-0739 Constructed ASN.1 types with a recursive definition (such as can be found in PKCS7) could eventually exceed the stack given malicious input with excessive recursion. This could result in a Denial Of Service attack. There are no such structures used within SSL/TLS that come from untrusted sources so this is considered safe. Fixed in OpenSSL 1.1.0h (Affected 1.1.0-1.1.0g). Fixed in OpenSSL 1.0.2o (Affected 1.0.2b-1.0.2n). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-674 Uncontrolled Recursion Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H CVE-2018-10612 In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2018-20025 Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-330 Use of Insufficiently Random Values Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2018-20026 Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-923 Improper Restriction of Communication Channel to Intended Endpoints Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2019-13532 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2019-13538 3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.6 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H CVE-2019-13542 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2019-13548 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-18858 CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-19789 3S-Smart CODESYS SP Realtime NT before V2.3.7.28, CODESYS Runtime Toolkit 32 bit full before V2.4.7.54, and CODESYS PLCWinNT before V2.4.7.54 allow a NULL pointer dereference. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2019-5105 An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9008 An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2019-9009 An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9010 An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2019-9011 In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), an attacker can identify valid usernames. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2019-9012 An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2019-9013 An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-327 Use of a Broken or Risky Cryptographic Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-10245 CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-12067 In Pilz PMC programming tool 3.x before 3.5.17 (based on CODESYS Development System), a user's password may be changed by an attacker without knowledge of the current password. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-640 Weak Password Recovery Mechanism for Forgotten Password Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-12068 An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-269 Improper Privilege Management Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2020-12069 In CODESYS V3 products in all versions prior V3.5.16.0 containing the CmpUserMgr, the CODESYS Control runtime system stores the online communication passwords using a weak hashing algorithm. This can be used by a local attacker with low privileges to gain full control of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-916 Use of Password Hash With Insufficient Computational Effort Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2020-14509 Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-805 Buffer Access with Incorrect Length Value Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-14513 CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2020-14515 CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-347 Improper Verification of Cryptographic Signature Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-14517 Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-326 Inadequate Encryption Strength Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2020-14519 This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-346 Origin Validation Error Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N CVE-2020-15806 CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2020-16233 An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2020-7052 CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-770 Allocation of Resources Without Limits or Throttling Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2021-21863 A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21864 A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21865 A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21866 A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21867 An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21868 An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-50 Path Equivalence: '//multiple/leading/slash' Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-21869 An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-29239 CODESYS Development System 3 before 3.5.17.0 displays or executes malicious documents or files embedded in libraries without first checking their validity. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-345 Insufficient Verification of Data Authenticity Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2021-29240 The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-345 Insufficient Verification of Data Authenticity Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2021-29241 CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS). View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-29242 CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level communication packages. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2021-30186 CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-30187 CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L CVE-2021-30188 CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-30190 CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-30195 CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-33485 CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2021-33486 All versions of the CODESYS V3 Runtime Toolkit for VxWorks from version V3.5.8.0 and before version V3.5.17.10 have Improper Handling of Exceptional Conditions. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-34593 In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-75 Failure to Sanitize Special Elements into a Different Plane (Special Element Injection) Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-34595 A crafted request with invalid offsets may cause an out-of-bounds read or write access in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition or local memory overwrite. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2021-34596 A crafted request may cause a read access to an uninitialized pointer in CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56, resulting in a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2021-36763 In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2021-36764 In CODESYS Gateway V3 before 3.5.17.10, there is a NULL Pointer Dereference. Crafted communication requests may cause a Null pointer dereference in the affected CODESYS products and may result in a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2021-36765 In CODESYS EtherNetIP before 4.1.0.0, specific EtherNet/IP requests may cause a null pointer dereference in the downloaded vulnerable EtherNet/IP stack that is executed by the CODESYS Control runtime system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 7.5 HIGH CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2022-1965 Multiple products of CODESYS implement a improper error handling. A low privilege remote attacker may craft a request, which is not properly processed by the error handling. In consequence, the file referenced by the request could be deleted. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-755 Improper Handling of Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2022-1989 All CODESYS Visualization versions before V4.2.0.0 generate a login dialog vulnerable to information exposure allowing a remote, unauthenticated attacker to enumerate valid users. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N CVE-2022-22508 Improper Input Validation vulnerability in multiple CODESYS V3 products allows an authenticated remote attacker to block consecutive logins of a specific type. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L CVE-2022-22513 An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-476 NULL Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.0 6.5 MEDIUM CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-22514 An authenticated, remote attacker can gain access to a dereferenced pointer contained in a request. The accesses can subsequently lead to local overwriting of memory in the CmpTraceMgr, whereby the attacker can neither gain the values read internally nor control the values to be written. If invalid memory is accessed, this results in a crash. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-822 Untrusted Pointer Dereference Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H CVE-2022-22515 A remote, authenticated attacker could utilize the control program of the CODESYS Control runtime system to use the vulnerability in order to read and modify the configuration file(s) of the affected products. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N CVE-2022-22516 The SysDrv3S driver in the CODESYS Control runtime system on Microsoft Windows allows any system user to read and write within restricted memory space. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-22517 An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-33 Path Traversal: '....' (Multiple Dot) Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-22519 A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-12 ASP.NET Misconfiguration: Missing Custom Error Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-30791 In CmpBlkDrvTcp of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new TCP connections. Existing connections are not affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-30792 In CmpChannelServer of CODESYS V3 in multiple versions an uncontrolled ressource consumption allows an unauthorized attacker to block new communication channel connections. Existing connections are not affected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-400 Uncontrolled Resource Consumption Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-31805 In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-523 Unprotected Transport of Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2022-31806 In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2022-32136 In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-82 Improper Neutralization of Script in Attributes of IMG Tags in a Web Page Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32137 In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-122 Heap-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-32138 In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-194 Unexpected Sign Extension Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-32139 In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32140 Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32141 Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-126 Buffer Over-read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-32142 Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-823 Use of Out-of-range Pointer Offset Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.1 HIGH CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H CVE-2022-32143 In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-4046 In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.0 8.8 HIGH CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-4048 Inadequate Encryption Strength in CODESYS Development System V3 versions prior to V3.5.18.40 allows an unauthenticated local attacker to access and manipulate code of the encrypted boot application. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-326 Inadequate Encryption Strength Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.7 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N CVE-2022-4224 In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-1188 Initialization of a Resource with an Insecure Default Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47378 Multiple CODESYS products in multiple versions are prone to a improper input validation vulnerability. An authenticated remote attacker may craft specific requests that use the vulnerability leading to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47379 An authenticated, remote attacker may use a out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into memory which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47380 An authenticated remote attacker may use a stack basedout-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47381 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47383 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47384 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47385 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpAppForce Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47386 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47387 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47388 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47389 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47390 An authenticated, remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-47391 In multiple CODESYS products in multiple versions an unauthorized, remote attacker may use a improper input validation vulnerability to read from invalid addresses leading to a denial of service. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2022-47392 An authenticated, remote attacker may use a improper input validation vulnerability in the CmpApp/CmpAppBP/CmpAppForce Components of multiple CODESYS products in multiple versions to read from an invalid address which can lead to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2022-47393 An authenticated, remote attacker may use a Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in multiple versions of multiple CODESYS products to force a denial-of-service situation. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-3662 In CODESYS Development System versions from 3.5.17.0 and prior to 3.5.19.20 a vulnerability allows for execution of binaries from the current working directory in the users context . View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-427 Uncontrolled Search Path Element Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2023-3663 In CODESYS Development System versions from 3.5.11.20 and before 3.5.19.20 a missing integrity check might allow an unauthenticated remote attacker to manipulate the content of notifications received via HTTP by the CODESYS notification server. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-940 Improper Verification of Source of a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2023-3669 A missing Brute-Force protection in CODESYS Development System prior to 3.5.19.20 allows a local attacker to have unlimited attempts of guessing the password within an import dialog. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 3.3 LOW CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N CVE-2023-3670 In CODESYS Development System 3.5.9.0 to 3.5.17.0 and CODESYS Scripting 4.0.0.0 to 4.1.0.0 unsafe directory permissions would allow an attacker with local access to the workstation to place potentially harmful and disguised scripts that could be executed by legitimate users. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-668 Exposure of Resource to Wrong Sphere Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H CVE-2023-37545 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37546, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549, CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37546 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37547 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37548 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37549 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37550 In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37551 In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-552 Files or Directories Accessible to External Parties Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N CVE-2023-37552 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37553 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37554 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37555 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37556 In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37557 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37558 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-37559 After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558 View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-20 Improper Input Validation Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H CVE-2023-3935 A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2023-49675 An unauthenticated local attacker may trick a user to open corrupted project files to execute arbitrary code or crash the system due to an out-of-bounds write vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2023-49676 An unauthenticated local attacker may trick a user to open corrupted project files to crash the system due to use after free vulnerability. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H CVE-2023-6357 A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2024-5000 An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-13 ASP.NET Misconfiguration: Password in Configuration File Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2024-8175 An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2025-0694 Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.6 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-1468 An unauthenticated remote attacker can gain access to sensitive information including authentication information when using CODESYS OPC UA Server with the non-default Basic128Rsa15 security policy. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-203 Observable Discrepancy Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N CVE-2025-41658 CODESYS Runtime Toolkit-based products may expose sensitive files to local low-privileged operating system users due to default file permissions. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-276 Incorrect Default Permissions Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N CVE-2025-41659 A low-privileged attacker can remotely access the PKI folder of the CODESYS Control runtime system and thus read and write certificates and its keys. This allows sensitive data to be extracted or to accept certificates as trusted. Although all services remain available, only unencrypted communication is possible if the certificates are deleted. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.3 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L CVE-2020-11023 In jQuery versions greater than or equal to 1.0.3 and before 3.5.0, passing HTML containing option elements from untrusted sources - even after sanitizing it - to one of jQuery's DOM manipulation methods (i.e. .html(), .append(), and others) may execute untrusted code. This problem is patched in jQuery 3.5.0. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:N CVE-2022-47382 An authenticated remote attacker may use a stack based out-of-bounds write vulnerability in the CmpTraceMgr Component of multiple CODESYS products in multiple versions to write data into the stack which can lead to a denial-of-service condition, memory overwriting, or remote code execution. View CVE Details Affected Products CODESYS in Festo Automation Suite Vendor: FESTO, CODESYS Product Version: FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (versions prior to 2.8.0.138) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.0): vers:all/*, FESTO, CODESYS FESTO Software Festo Automation Suite (2.8.0.137) installed with CODESYS Software CODESYS Development System (3.5.16.10): vers:all/* Product Status: known_affected Remediations Mitigation FESTO has identified the following specific workarounds and mitigations users can apply to reduce risk: Mitigation Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo. Mitigation The following product versions have been fixed: Mitigation CODESYS Development System 3.5.21.20 as an external component of Festo Automation Suite 2.8.0.138 are fixed versions for all CVEs Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://festo.csaf-tp.certvde.com/.well-known/csaf/white/2026/fsa-202601.json Mitigation For more information see the associated Festo SE & Co. KG security advisory FSA-202601 FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - CSAF, FSA-202601: Several CODESYS vulnerabilities in Festo Automation Suite - HTML. https://certvde.com/en/advisories/VDE-2025-108 Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments CERT@VDE reported this vulnerability to Festo Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-17 Date Revision Summary 2026-03-17 1 Initial Republication of Festo SE & Co. KG FSA-202601 Legal Notice and Terms of Use
View CSAF Summary Schneider Electric is aware of a hard-coded credentials vulnerability in its EcoStruxure IT Data Center Expert (DCE) product that requires administrator credentials and enabling a feature (SOCKS Proxy) that is off by default. The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure, and remote compromise of the offer which could result in disruption of operations and access to system data. The following versions of Schneider Electric EcoStruxure Data Center Expert are affected: EcoStruxure IT Data Center Expert vers:intdot/<=9.0 EcoStruxure IT Data Center Expert 9.1 CVSS Vendor Equipment Vulnerabilities v3 7.2 Schneider Electric Schneider Electric EcoStruxure Data Center Expert Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13957 A hard-coded credentials vulnerability exists that could lead to information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. View CVE Details Affected Products Schneider Electric EcoStruxure Data Center Expert Vendor: Schneider Electric Product Version: EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) v9.0 and prior Product Status: fixed, known_affected Remediations Vendor fix v9.1 of EcoStruxure IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data-center-expert/#software-and-firmware Mitigation If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Harden the DCE instance according to the cybersecurity best practices documented in the EcoStruxure IT Data Center Expert Security Handbook • Ensure the SOCKS Proxy is disabled as in the default configuration. Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert PDF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-05.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert CSAF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-05.json Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments hassan ali of TrendAI Zero Day Initiative reported this vulnerability to Schneider Electric General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices: * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-05 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric SEVD-2026-069-05 advisory Legal Notice and Terms of Use
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. The following versions of Schneider Electric SCADAPack and RemoteConnect are affected: SCADAPack™ vers:generic/ SCADAPack™ firmware vers:intdot/<9.12.2, 9.12.2, vers:intdot/<9.12.2, 9.12.2 () RemoteConnect vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric SCADAPack and RemoteConnect Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-0667 CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol. View CVE Details Affected Products Schneider Electric SCADAPack and RemoteConnect Vendor: Schneider Electric Product Version: SCADAPack™ 57x All Versions, RemoteConnect Versions prior to R3.4.2 Product Status: fixed, known_affected Remediations Vendor fix Version R3.4.2 (Firmware version 9.12.2) of SCADAPack™ 47x and SCADAPack™ 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Vendor fix Version R3.4.2 of RemoteConnect includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service. Mitigation Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services. • Disable the logic debug service. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-041-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-10 Date Revision Summary 2026-02-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-041-01 advisory Legal Notice and Terms of Use
Equipment for smart European cable systems - Works Anonymous (not verified) Tue, 03/17/2026 - 08:45 Opening: 17 March 2026 Closing: 30 June 2026 This call supports the upgrade of existing submarine telecommunications/digital infrastructures to “smart capabilities” enabling applications that monitor them as well as other surrounding critical infrastructures (e.g. power cables, pipelines, etc.) and/or their vicinity. Main link https://ec.europa.eu/info/funding-tenders/opportunities/portal/screen/opportuni… Related topics Digital connectivity Connecting Europe Facility Funding for Digital {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
Backbone connectivity for Digital Global Gateways - Studies Anonymous (not verified) Tue, 03/17/2026 - 08:19 Opening: 17 March 2026 Closing: 30 June 2026 This call for proposals will fund studies related to the deployment/significant upgrade of backbone networks that address risks, vulnerabilities and dependencies in the EU backbone infrastructure. GettyImages © Dragon Claws Main link https://ec.europa.eu/info/funding-tenders/opportunities/portal/screen/opportuni… Related topics Digital connectivity Connecting Europe Facility Funding for Digital {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-47813 Wing FTP Server Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Open EU Foundry status granted to innovative chiplet facility Anonymous (not verified) Mon, 03/16/2026 - 10:40 The Commission has granted the Open EU Foundry (OEF) status to Silicon Box in Novara, Italy. GettyImages © Nikola Ilic - E+ Under the European Chips Act, the OEF status is granted to new or upgraded innovative semiconductor manufacturing facilities. The status provides benefits to semiconductor facilities including administrative support, faster construction approvals and priority access to pilot lines under the Chips for Europe Initiative. This helps deepen European semiconductor supply chain resilience and boost innovation. Silicon Box’s project is a significant milestone in strengthening Europe’s semiconductor industry through its new advanced semiconductor packaging and testing facility. The facility will integrate multiple dies or chiplets - small, modular semiconductor blocks that perform specific functions - into a single package, effectively creating a multi-chip module that behaves like a single chip, using panel level packaging. Panel level packaging uses a more efficient large-panel approach to packaging, enabling higher output and lower cost compared to traditional methods in the final stage of the chip making process. The facility will also test chips at panel-level, grouping multiple chiplets into a single panel, enabling more comprehensive quality verification before final assembly. The project will provide an important base in Europe for developing innovative technologies, products and system solutions for the semiconductors key to powering AI, electric and autonomous vehicles, data centres, as well as supercomputing applications. The plant is expected to reach full capacity in 2033. This OEF status recognition follows four semiconductor projects across the EU which have previously been awarded OEF or IPF (integrated production facility) status in October 2025: ESMC in Germany (OEF) Ams-OSRAM in Austria (IPF) Infineon Technologies Dresden in Germany (IPF) STMicroelectronics in Italy The decision to grant OEF follows the Commission state aid decision concerning Silicon Box. Related topics Advanced Digital Technologies Electronics Chips Act Semiconductors {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3909 Google Skia Out-of-Bounds Write Vulnerability CVE-2026-3910 Google Chromium V8 Unspecified Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, execute arbitrary commands, or perform a denial-of-service on the product. The following versions of Trane Tracer SC, Tracer SC+, and Tracer Concierge are affected: Tracer SC Tracer SC+ Tracer Concierge CVSS Vendor Equipment Vulnerabilities v3 8.1 Trane Trane Tracer SC, Tracer SC+, and Tracer Concierge Use of a Broken or Risky Cryptographic Algorithm, Memory Allocation with Excessive Size Value, Missing Authorization, Use of Hard-coded Credentials, Use of Hard-coded, Security-relevant Constants Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Ireland Vulnerabilities Expand All + CVE-2026-28252 A Use of a Broken or Risky Cryptographic Algorithm vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge could allow an attacker to bypass authentication and gain root-level access to the device. View CVE Details Affected Products Trane Tracer SC, Tracer SC+, and Tracer Concierge Vendor: Trane Product Version: Trane Tracer SC:
Apply AI webinars sectoral deep dive - Agrifood, climate & environment Anonymous (not verified) Thu, 03/05/2026 - 14:30 19 March 2026 This session focuses on how the Commission, together with the private sector, aims to accelerate AI adoption across the agrifood sector, as well as the intersection between AI, climate and environment. This is part of a series of Apply AI thematic webinars. Join the live stream on our YouTube channel to find out how farmers, industry, researchers and other stakeholders can contribute to shaping priorities for Europe’s agrifood, climate and environment ecosystems. Engage in the conversation by submitting questions in advance or during the session via Slido. Agenda 14:00 - 14:45 (CET) Apply AI Agrifood 14:45 - 15:00 (CET) Short break 15:00 - 15:45 (CET) Apply AI Climate & Environment Download the slides for both sessions below. Moderator Andrea Hak, Stakeholder Communication Expert at the AI Office, DG CONNECT Speakers - Agrifood Pierluigi Londero, Head of Unit Data Governance, DG AGRI Doris Marquardt, Programme Officer EU Policies, Contact person for Agriculture in the DG, DG CONNECT Speakers - Climate & Environment Tsitlakidis Charalampos, Head of Sector, Destination Earth, DG CONNECT Irina Sandu, Director of Destination Earth (DestinE), European Centre for Medium-Range Weather Forecasts (ECMWF) Agrifood The webinar will discuss how the Commission aims to accelerate AI adoption across the agrifood sector and translate innovation into impact on the ground, enhancing sectorial competitiveness and public goods. Among others, a marketplace for AI-based solutions for the agri-food sector will be introduced and funding will be devoted to capacity building in the development of agriculture specific foundation models (e.g., LLMs). AI is already reshaping agricultural production and can transform the way food is produced, benefiting the environment, climate and people. AI supports farmers, for instance through AI-driven advisory tools and handy applications that turn data into tailored recommendations. These help producers to make better and faster decisions accounting for local conditions, and increasing resource efficiency, e.g. saving water, and effectiveness. A new wave of opportunities is emerging, boosting precision farming, powering robots, and smartening machinery for field work. AI can also contribute to reducing reporting obligations and other administrative burdens. Climate & Environment AI has a long track record in environmental monitoring, forecasting, and Earth observation. It can enhance early-warning systems and aid disaster response as well as decision-making for resilience and climate preparedness. Ground-breaking initiatives such as Destination Earth provide high-resolution and interactive simulations with unprecedented predictive power through AI-driven applications. Downloads Apply AI Climate & Environment (PDF) Download Related topics Creating a digital society Environment Smart and Sustainable Communities Artificial intelligence {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
Commission holds first meeting of Special Panel on child safety online Anonymous (not verified) Thu, 03/05/2026 - 08:08 European Commission President Ursula von der Leyen hosted the first meeting of the Special Panel on child safety online. AdobeStock ©myboys The panel, announced in the 2025 State of the Union address, will provide expert recommendations to better protect and empower children online and will explore the need for potential harmonised age restrictions to access social media. President Ursula von der Leyen said: For decades, we have made the real world safer for children and we must do the same in the digital world. The positive opportunities that technology offers cannot come at the cost of their safety, health or happiness. In Europe, tech platforms already have a responsibility to ensure the safety of users and we will continue to ensure they do so. But we must also do more to protect and empower our young people online. That is why I have convened this panel: to forge a strong, realistic, European approach to keep our children safe in the digital age. Read the full press release and find further information about the special panel on child safety online. Related to child safety online, you can also read more about: the Digital Services Act (DSA) and its Guidelines on the protection of minors the Safer Internet Centres under the Better Internet for Kids Strategy (BIK+) the Cyberbullying Action Plan the EU Age Verification solution the Communication on a comprehensive approach to mental health the EU rules to combat child sexual abuse online Related topics Better Internet for Children Strengthening trust and security Online platforms and e-commerce {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}