Flux RSS

— Sources secondaires
71articles RSS
Reinitialiser
CISA Flags Critical PTC Vulnerability That Had German Police Mobilized
Vulnérabilités & PatchesSecurityWeekil y a 4 jours

Police in Germany physically warned organizations about the critical PTC Windchill vulnerability tracked as CVE-2026-4681. The post CISA Flags Critical PTC Vulnerability That Had German Police Mobilized appeared first on SecurityWeek.

Hightower Holding Data Breach Impacts 130,000
Gouvernance & RégulationSecurityWeekil y a 5 jours

The holdings company says hackers stole names, Social Security numbers, and driver’s license numbers from its environment. The post Hightower Holding Data Breach Impacts 130,000 appeared first on SecurityWeek.

BIND Updates Patch High-Severity Vulnerabilities
Vulnérabilités & PatchesSecurityWeekil y a 5 jours

Specially crafted domains could be used to cause out-of-memory conditions, leading to memory leaks in the BIND resolvers. The post BIND Updates Patch High-Severity Vulnerabilities appeared first on SecurityWeek.

Chinese Hackers Caught Deep Within Telecom Backbone Infrastructure
Malware & RansomwareSecurityWeekil y a 5 jours

The state-sponsored threat actor deployed kernel implants and passive backdoors enabling long-term, high-level espionage. The post Chinese Hackers Caught Deep Within Telecom Backbone Infrastructure appeared first on SecurityWeek.

Cisco Patches Multiple Vulnerabilities in IOS Software
Gouvernance & RégulationSecurityWeekil y a 5 jours

The high- and medium-severity flaws could lead to denial-of-service, secure boot bypass, information disclosure, and privilege escalation. The post Cisco Patches Multiple Vulnerabilities in IOS Software appeared first on SecurityWeek.

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33634 Aqua Security Trivy Embedded Malicious Code Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

PTC Windchill Product Lifecycle Management
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. The following versions of PTC Windchill Product Lifecycle Management are affected: Windchill PDMLink 11.0_M030 (CVE-2026-4681) Windchill PDMLink 11.1_M020 (CVE-2026-4681) Windchill PDMLink 11.2.1.0 (CVE-2026-4681) Windchill PDMLink 12.0.2.0 (CVE-2026-4681) Windchill PDMLink 12.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.0.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.0.0 (CVE-2026-4681) Windchill PDMLink 13.1.1.0 (CVE-2026-4681) Windchill PDMLink 13.1.2.0 (CVE-2026-4681) Windchill PDMLink 13.1.3.0 (CVE-2026-4681) FlexPLM 11.0_M030 (CVE-2026-4681) FlexPLM 11.1_M020 (CVE-2026-4681) FlexPLM 11.2.1.0 (CVE-2026-4681) FlexPLM 12.0.0.0 (CVE-2026-4681) FlexPLM 12.0.2.0 (CVE-2026-4681) FlexPLM 12.0.3.0 (CVE-2026-4681) FlexPLM 12.1.2.0 (CVE-2026-4681) FlexPLM 12.1.3.0 (CVE-2026-4681) FlexPLM 13.0.2.0 (CVE-2026-4681) FlexPLM 13.0.3.0 (CVE-2026-4681) CVSS Vendor Equipment Vulnerabilities v3 10 PTC PTC Windchill Product Lifecycle Management Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-4681 A critical remote code execution (RCE) vulnerability has been reported in PTC Windchill and PTC FlexPLM. The vulnerability may be exploited through the deserialization of untrusted data. This issue affects Windchill PDMLink: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.2.0, 12.1.2.0, 13.0.2.0, 13.1.0.0, 13.1.1.0, 13.1.2.0, 13.1.3.0; FlexPLM: 11.0 M030, 11.1 M020, 11.2.1.0, 12.0.0.0, 12.0.2.0, 12.0.3.0, 12.1.2.0, 12.1.3.0, 13.0.2.0, 13.0.3.0. View CVE Details Affected Products PTC Windchill Product Lifecycle Management Vendor: PTC Product Version: PTC Windchill PDMLink: 11.0_M030, PTC Windchill PDMLink: 11.1_M020, PTC Windchill PDMLink: 11.2.1.0, PTC Windchill PDMLink: 12.0.2.0, PTC Windchill PDMLink: 12.1.2.0, PTC Windchill PDMLink: 13.0.2.0, PTC Windchill PDMLink: 13.1.0.0, PTC Windchill PDMLink: 13.1.1.0, PTC Windchill PDMLink: 13.1.2.0, PTC Windchill PDMLink: 13.1.3.0, PTC FlexPLM: 11.0_M030, PTC FlexPLM: 11.1_M020, PTC FlexPLM: 11.2.1.0, PTC FlexPLM: 12.0.0.0, PTC FlexPLM: 12.0.2.0, PTC FlexPLM: 12.0.3.0, PTC FlexPLM: 12.1.2.0, PTC FlexPLM: 12.1.3.0, PTC FlexPLM: 13.0.2.0, PTC FlexPLM: 13.0.3.0 Product Status: known_affected Remediations Mitigation PTC is aware of the issue and is actively developing a fix. In the meantime, PTC recommends applying the recommended workaround. Until official patches are available, customers must take urgent steps to safeguard their environments. Specifically: Protect any publicly accessible Windchill systems Vendor fix While publicly accessible Windchill and FlexPLM systems are at higher risk and require immediate attention, PTC strongly recommends applying the mitigation steps to all deployments, regardless of Internet exposure Vendor fix Apply the same precautions to FlexPLM deployments Vendor fix The following Apache and IIS HTTP Server configuration update should be IMMEDIATELY applied to every Windchill or FlexPLM system: Customers using Apache HTTP Server should only follow "Apache HTTP Server Configuration – Workaround Steps" section steps Mitigation Customers using Microsoft IIS should only follow "IIS Configuration - Workaround Steps" section steps Mitigation Please explicitly note that the same mitigation steps must also be applied on File Server / Replica Server configurations where applicable Mitigation For Windchill releases prior to 11.0 M030, workarounds may need to be altered to apply to unsupported previous releases Mitigation For Apache HTTP Server and IIS configuration workaround steps, please refer to the official advisory at:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Mitigation If immediate remediation is not feasible, additional guidance and remediation options are available:https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability. https://www.ptc.com/en/about/trust-center/advisory-center/active-advisories/windchill-flexplm-critical-vulnerability Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments An anonymous source reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of PTC's CS466318 Legal Notice and Terms of Use

OpenCode Systems OC Messaging and USSD Gateway
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated low-privileged user to gain access to SMS messages outside of their authorized tenant scope via a crafted company or tenant identifier parameter. The following versions of OpenCode Systems OC Messaging and USSD Gateway are affected: OC Messaging 6.32.2 (CVE-2025-70614) USSD Gateway 6.32.2 (CVE-2025-70614) CVSS Vendor Equipment Vulnerabilities v3 8.1 OpenCode Systems OpenCode Systems OC Messaging and USSD Gateway Improper Access Control Background Critical Infrastructure Sectors: Communications Countries/Areas Deployed: Worldwide Company Headquarters Location: Bulgaria Vulnerabilities Expand All + CVE-2025-70614 OpenCode Systems Custom Messaging Gateway 6.32.2 contains a web access vulnerability allowing one authenticated user to gain access to another authenticated user's messages via a crafted identifier parameter. View CVE Details Affected Products OpenCode Systems OC Messaging and USSD Gateway Vendor: OpenCode Systems Product Version: OpenCode Systems OC Messaging: 6.32.2, OpenCode Systems USSD Gateway: 6.32.2 Product Status: known_affected Remediations Mitigation The vulnerability was identified by OpenCode Systems on January 5, 2026 and remediated on January 6, 2026 with the release of version 6.33.11. Mitigation For more information, contact OpenCode: https://opencode.com/about/contact-us https://opencode.com/about/contact-us Relevant CWE: CWE-284 Improper Access Control Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.1 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N Acknowledgments Hussein Amer reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Publication Legal Notice and Terms of Use

WAGO GmbH & Co. KG Industrial Managed Switches
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. The following versions of WAGO GmbH & Co. KG Industrial Managed Switches are affected: WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware versions prior to V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware versions prior to V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware versions prior to V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-602 (CVE-2026-3587) WAGO Firmware version V1.0.6.S0 WAGO_Hardware_852-603 (CVE-2026-3587) WAGO Firmware version V1.1.9.S0 WAGO_Hardware_852-1505 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1305/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.0.S0 WAGO_Hardware_852-1505/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1812/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1816/010-000 (CVE-2026-3587) WAGO Firmware version V1.2.3.S0 WAGO_Hardware_852-1813/000-001 (CVE-2026-3587) WAGO Firmware version V1.2.5.S0 WAGO_Hardware_852-1605 (CVE-2026-3587) WAGO Firmware version V1.2.8.S0 WAGO_Hardware_852-303 (CVE-2026-3587) WAGO Firmware version V1.2.1.S0 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) WAGO Firmware version V1.2.1.S1 WAGO_Hardware_852-1813/010-001 (CVE-2026-3587) CVSS Vendor Equipment Vulnerabilities v3 10 WAGO WAGO GmbH & Co. KG Industrial Managed Switches Hidden Functionality Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-3587 An unauthenticated remote attacker can exploit a hidden function in the CLI prompt to escape the restricted interface, leading to full compromise of the device. View CVE Details Affected Products WAGO GmbH & Co. KG Industrial Managed Switches Vendor: WAGO Product Version: WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware versions prior to V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware versions prior to V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware versions prior to V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware versions prior to V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware versions prior to V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware versions prior to V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware versions prior to V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-602, WAGO WAGO Firmware version V1.0.6.S0: WAGO_Hardware_852-603, WAGO WAGO Firmware version V1.1.9.S0: WAGO_Hardware_852-1505, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1305/000-001, WAGO WAGO Firmware version V1.2.0.S0: WAGO_Hardware_852-1505/000-001, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1812/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-000, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1816/010-000, WAGO WAGO Firmware version V1.2.3.S0: WAGO_Hardware_852-1813/000-001, WAGO WAGO Firmware version V1.2.5.S0: WAGO_Hardware_852-1605, WAGO WAGO Firmware version V1.2.8.S0: WAGO_Hardware_852-303, WAGO WAGO Firmware version V1.2.1.S0: WAGO_Hardware_852-1813/010-001, WAGO WAGO Firmware version V1.2.1.S1: WAGO_Hardware_852-1813/010-001 Product Status: known_affected Remediations Mitigation WAGO has identified the following specific workarounds and mitigations users can apply to reduce risk: Product Group: WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-602, WAGO Firmware installed on WAGO Hardware 852-603, WAGO Firmware installed on WAGO Hardware 852-1505, WAGO Firmware installed on WAGO Hardware 852-1305, WAGO Firmware installed on WAGO Hardware 852-1305/000-001, WAGO Firmware installed on WAGO Hardware 852-1505/000-001, WAGO Firmware installed on WAGO Hardware 852-1812, WAGO Firmware installed on WAGO Hardware 852-1813, WAGO Firmware installed on WAGO Hardware 852-1816, WAGO Firmware installed on WAGO Hardware 852-1812/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/010-000, WAGO Firmware installed on WAGO Hardware 852-1816/010-000, WAGO Firmware installed on WAGO Hardware 852-1813/000-001, WAGO Firmware installed on WAGO Hardware 852-1605, WAGO Firmware installed on WAGO Hardware 852-303, WAGO Firmware installed on WAGO Hardware 852-1813/010-001, WAGO Firmware installed on WAGO Hardware 852-1813/010-001): Please update your devices to the specified fixed Firmware version. Mitigation Lean Managed Switch 852-1812, Lean Managed Switch 852-1813, Lean Managed Switch 852-1813/000-001, Lean Managed Switch 852-1816, Lean Managed Switch 852-1812/010-000, Lean Managed Switch 852-1813/010-000, Lean Managed Switch 852-1816/010-000, Lean Managed Switch 852-1813/010-001: To eliminate the attack vector deactivate ssh and telnet on the device. Mitigation Industrial Managed Switch 852-303, Industrial Managed Switch 852-1305, Industrial Managed Switch 852-1305/000-001, Industrial Managed Switch 852-1505/000-001, Industrial Managed Switch 852-1505, Industrial Managed Switch 852-602, Industrial Managed Switch 852-603, Industrial Managed Switch 852-1605: To reduce the attack vector deactivate ssh and telnet on the devices. This ensures that the CLI is only accessible locally via RS232. Mitigation The following product versions have been fixed: Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.3.S1 installed on Lean Managed Switch 852-1813/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.8.S1 installed on Industrial Managed Switch 852-303 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1305/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.0.S1 installed on Industrial Managed Switch 852-1505/000-001 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.1.9.S1 installed on Industrial Managed Switch 852-1505 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-602 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.0.6.S1 installed on Industrial Managed Switch 852-603 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.5.S1 installed on Industrial Managed Switch 852-1605 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1812/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1816/010-000 are fixed versions for CVE-2026-3587 Mitigation Firmware V1.2.1.S1 installed on Lean Managed Switch 852-1813/010-001 are fixed versions for CVE-2026-3587 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://www.wago.com/de-en/automation-technology/psirt Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://certvde.com/en/advisories/VDE-2026-020 Mitigation For more information see the associated WAGO GmbH & Co. KG security advisory VDE-2026-020 WAGO PSIRT: https://www.wago.com/de-en/automation-technology/psirt. VDE-2026-020: WAGO: Vulnerability in managed switches - HTML: https://certvde.com/en/advisories/VDE-2026-020. VDE-2026-020: WAGO: Vulnerability in managed switches - CSAF: https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json. https://wago.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-020.json Relevant CWE: CWE-912 Hidden Functionality Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments CERT@VDE coordination reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-26 Date Revision Summary 2026-03-26 1 Initial Republication of WAGO GmbH & Co. KG VDE-2026-020 Legal Notice and Terms of Use

Alleged RedLine Malware Administrator Extradited to US
Malware & RansomwareSecurityWeekil y a 5 jours

Hambardzum Minasyan of Armenia has been accused of being involved in the development and administration of the infostealer malware. The post Alleged RedLine Malware Administrator Extradited to US appeared first on SecurityWeek.

Commission preliminarily finds Pornhub, Stripchat, XNXX and XVideos in breach of the Digital Services Act for allowing minors to access their services
Gouvernance & RégulationEC Digital Strategyil y a 5 jours

Commission preliminarily finds Pornhub, Stripchat, XNXX and XVideos in breach of the Digital Services Act for allowing minors to access their services Anonymous (not verified) Thu, 03/26/2026 - 09:39 The European Commission preliminarily found Pornhub, Stripchat, XNXX and XVideos in breach of the Digital Services Act (DSA) for failing to protect minors from being exposed to pornographic content on their services. In exercising their right of defence, XVideos, XNXX, Pornhub and Stripchat now have the possibility to examine the documents in the Commission's investigation files and reply in writing to the Commission's preliminary findings. Read the full press release and find further information about the: Digital Services Act - main aspects of the regulation User rights under the Digital Services Act - an overview Protecting and empowering young people online Supervision of the designated very large online platforms and search engines under DSA Related topics Better Internet for Children Strengthening trust and security Online platforms and e-commerce DSA - Digital Services Act {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}

Commission investigates Snapchat's compliance with child protection rules under the Digital Services Act
Gouvernance & RégulationEC Digital Strategyil y a 5 jours

Commission investigates Snapchat's compliance with child protection rules under the Digital Services Act Anonymous (not verified) Thu, 03/26/2026 - 09:39 The European Commission has opened formal proceedings to investigate if Snapchat is ensuring a high level of safety, privacy and security for children online, in compliance with the Digital Services Act (DSA). Snapchat may have breached the DSA by exposing minors to grooming attempts and recruitment for criminal purposes, as well as to information about the sale of illegal goods, like drugs, or age-restricted products, such as vapes and alcohol. The investigation will focus on five areas. Read the full press release and more information about the Commission services and Dutch Digital Services Coordinator joint investigation. Find further information about the: Digital Services Act- main aspects of the regulation User rights under the Digital Services Act- an overview Protecting and empowering young people online Supervision of the designated very large online platforms and search engines under DSA Related topics Better Internet for Children Strengthening trust and security Online platforms and e-commerce DSA - Digital Services Act {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}

Onit Security Raises $11 Million for Exposure Management Platform
Gouvernance & RégulationSecurityWeekil y a 6 jours

The startup will invest in product development and go-to-market efforts as it expands into new sectors. The post Onit Security Raises $11 Million for Exposure Management Platform appeared first on SecurityWeek.

Russian Cybercriminal Gets 2-Year Prison Sentence in US
GénéralSecurityWeekil y a 6 jours

Ilya Angelov was a member of the cybercrime group tracked as TA-551, Shathak, Gold Cabin, Monster Libra, and ATK236. The post Russian Cybercriminal Gets 2-Year Prison Sentence in US appeared first on SecurityWeek.

iOS, macOS 26.4 Roll Out With Fresh Security Patches
Vulnérabilités & PatchesSecurityWeekil y a 6 jours

Apple released security fixes for older devices as well, in iOS 18.7.7, iPadOS 18.7.7, macOS Sequoia 15.7.5, and macOS Sonoma 14.8.5. The post iOS, macOS 26.4 Roll Out With Fresh Security Patches appeared first on SecurityWeek.

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 6 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33017 Langflow Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Pharos Controls Mosaic Show Controller
Gouvernance & RégulationCISA Advisoriesil y a 7 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges. The following versions of Pharos Controls Mosaic Show Controller are affected: Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pharos Controls Pharos Controls Mosaic Show Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-2417 A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges. View CVE Details Affected Products Pharos Controls Mosaic Show Controller Vendor: Pharos Controls Product Version: Pharos Controls Mosaic Show Controller Firmware: 2.15.3 Product Status: known_affected Remediations Mitigation Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments James Tully reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication Legal Notice and Terms of Use

Schneider Electric Plant iT/Brewmaxx
Gouvernance & RégulationCISA Advisoriesil y a 7 jours

View CSAF Summary Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution. The following versions of Schneider Electric Plant iT/Brewmaxx are affected: Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819) CVSS Vendor Equipment Vulnerabilities v3 9.9 Schneider Electric Schneider Electric Plant iT/Brewmaxx Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-49844 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-46817 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-46818 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N CVE-2025-46819 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H Acknowledgments Schneider Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Republication of SEVD-2026-013-01 Legal Notice and Terms of Use