Flux RSS

— Sources secondaires
122articles RSS
Reinitialiser
Commission investigates Snapchat's compliance with child protection rules under the Digital Services Act
Gouvernance & RégulationEC Digital Strategyil y a 3 jours

Commission investigates Snapchat's compliance with child protection rules under the Digital Services Act Anonymous (not verified) Thu, 03/26/2026 - 09:39 The European Commission has opened formal proceedings to investigate if Snapchat is ensuring a high level of safety, privacy and security for children online, in compliance with the Digital Services Act (DSA). Snapchat may have breached the DSA by exposing minors to grooming attempts and recruitment for criminal purposes, as well as to information about the sale of illegal goods, like drugs, or age-restricted products, such as vapes and alcohol. The investigation will focus on five areas. Read the full press release and more information about the Commission services and Dutch Digital Services Coordinator joint investigation. Find further information about the: Digital Services Act- main aspects of the regulation User rights under the Digital Services Act- an overview Protecting and empowering young people online Supervision of the designated very large online platforms and search engines under DSA Related topics Better Internet for Children Strengthening trust and security Online platforms and e-commerce DSA - Digital Services Act {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}

PolyShell attacks target 56% of all vulnerable Magento stores
Vulnérabilités & PatchesBleepingComputeril y a 3 jours

Attacks leveraging the 'PolyShell' vulnerability in version 2 of Magento Open Source and Adobe Commerce installations are underway, targeting more than half of all vulnerable stores. [...]

Onit Security Raises $11 Million for Exposure Management Platform
Gouvernance & RégulationSecurityWeekil y a 3 jours

The startup will invest in product development and go-to-market efforts as it expands into new sectors. The post Onit Security Raises $11 Million for Exposure Management Platform appeared first on SecurityWeek.

Russian Cybercriminal Gets 2-Year Prison Sentence in US
GénéralSecurityWeekil y a 3 jours

Ilya Angelov was a member of the cybercrime group tracked as TA-551, Shathak, Gold Cabin, Monster Libra, and ATK236. The post Russian Cybercriminal Gets 2-Year Prison Sentence in US appeared first on SecurityWeek.

Paid AI Accounts Are Now a Hot Underground Commodity
GénéralBleepingComputeril y a 3 jours

AI accounts are becoming part of the cybercrime supply chain, sold like email accounts or VPS access. Flare Systems shows how underground markets bundle and resell premium AI access at scale. [...]

iOS, macOS 26.4 Roll Out With Fresh Security Patches
Vulnérabilités & PatchesSecurityWeekil y a 3 jours

Apple released security fixes for older devices as well, in iOS 18.7.7, iPadOS 18.7.7, macOS Sequoia 15.7.5, and macOS Sonoma 14.8.5. The post iOS, macOS 26.4 Roll Out With Fresh Security Patches appeared first on SecurityWeek.

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 4 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33017 Langflow Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Circulaire CSSF 26/908 : Modification de la circulaire CSSF 18/703 sur le reporting semestriel des indicateurs immobiliers résidentiels
Gouvernance & RégulationCSSF Publicationsil y a 4 jours

La CSSF a mis à jour le 25 mars 2026 la circulaire CSSF 18/703 concernant le reporting semestriel des indicateurs liés aux emprunteurs pour l'immobilier résidentiel. Cette modification vise à adapter les exigences de déclaration pour les institutions financières luxembourgeoises. Impact direct sur les processus de reporting des entités supervisées.

How one man used 10,000 bots to steal $8,000,000 from music artists
GénéralGraham Cluleyil y a 4 jours

A man has pleaded guilty to defrauding online music streaming platforms out of more than US $8 million, after creating hundreds of thousands of songs with AI, and then using bots to play them billions of times. Read more in my article on the Hot for Security blog.

Pharos Controls Mosaic Show Controller
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges. The following versions of Pharos Controls Mosaic Show Controller are affected: Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pharos Controls Pharos Controls Mosaic Show Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-2417 A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges. View CVE Details Affected Products Pharos Controls Mosaic Show Controller Vendor: Pharos Controls Product Version: Pharos Controls Mosaic Show Controller Firmware: 2.15.3 Product Status: known_affected Remediations Mitigation Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments James Tully reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication Legal Notice and Terms of Use

Schneider Electric Plant iT/Brewmaxx
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution. The following versions of Schneider Electric Plant iT/Brewmaxx are affected: Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819) CVSS Vendor Equipment Vulnerabilities v3 9.9 Schneider Electric Schneider Electric Plant iT/Brewmaxx Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-49844 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-46817 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-46818 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N CVE-2025-46819 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H Acknowledgments Schneider Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Republication of SEVD-2026-013-01 Legal Notice and Terms of Use