Publicly accusing an entity of a cyberattack could have negative consequences that organizations should consider before taking the plunge.
Flux RSS
— Sources secondairesCitrix has patched two NetScaler ADC and NetScaler Gateway vulnerabilities, one of which is very similar to the CitrixBleed and CitrixBleed2 flaws exploited in zero-day attacks in recent years. [...]
A series of campaigns that began in August aim to defraud job candidates, using psychological tactics and data scraped from LinkedIn profiles.
Ten finalists will each have three minutes to make their case for being the most innovative, promising young security company of the year. Geordie AI wins the 2026 contest.
For the first time, SANS Institute's five top attack techniques all have one thing in common — AI.
Organizations disclose attack details, though information may be limited, following a breach, but what if they did the same with close calls?
AI accounts are becoming part of the cybercrime supply chain, sold like email accounts or VPS access. Flare Systems shows how underground markets bundle and resell premium AI access at scale. [...]
Attacks by artificial intelligence agents are a reality. Experts at Nvidia's GTC conference say defenders need to use the same tools to fight them off.
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-33017 Langflow Code Injection Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Four former NSA chiefs representing a near-complete history of US Cyber Command debate the role of offensive cyber in the government at RSAC.
A man has pleaded guilty to defrauding online music streaming platforms out of more than US $8 million, after creating hundreds of thousands of songs with AI, and then using bots to play them billions of times. Read more in my article on the Hot for Security blog.
Iran-aligned groups are trying to make their mark in the Gulf, but the results have fallen short of remarkable.
The Cloud Security Alliance creates a dedicated nonprofit to govern autonomous AI agent ecosystems through risk intelligence and certification.
TeamPCP is the likely cyber threat actor behind attacks on Trivy, Checkmarx's KICS and VS Code plug-ins, and the LiteLLM AI library — and all signs point to more attacks to come.
Security vendors have spent years building up defenses around the endpoint, but one researcher says AI coding tools have brought the walls down.
An AI-assisted campaign is spreading more than 300 poisoned packages for diverse assets ranging from developer tools to game cheats.
JPMorganChase uses digital fingerprints and digital twins to spot online attackers and malicious behaviors while also reducing pesky false alerts.
Companies need better controls to manage key threats rising from the growth of agentic AI. These new features provide a starting point.
View CSAF Summary Successful exploitation of this vulnerability could allow an unauthenticated attacker to execute arbitrary commands with root privileges. The following versions of Pharos Controls Mosaic Show Controller are affected: Mosaic Show Controller Firmware 2.15.3 (CVE-2026-2417) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pharos Controls Pharos Controls Mosaic Show Controller Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: United Kingdom Vulnerabilities Expand All + CVE-2026-2417 A Missing Authentication for Critical Function vulnerability in Pharos Controls Mosaic Show Controller firmware version 2.15.3 could allow an unauthenticated attacker to bypass authentication and execute arbitrary commands with root privileges. View CVE Details Affected Products Pharos Controls Mosaic Show Controller Vendor: Pharos Controls Product Version: Pharos Controls Mosaic Show Controller Firmware: 2.15.3 Product Status: known_affected Remediations Mitigation Pharos Controls recommends that users upgrade Mosaic Show Controller to version 2.16 or later. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments James Tully reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution. The following versions of Schneider Electric Plant iT/Brewmaxx are affected: Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819) CVSS Vendor Equipment Vulnerabilities v3 9.9 Schneider Electric Schneider Electric Plant iT/Brewmaxx Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-49844 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-46817 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-46818 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N CVE-2025-46819 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H Acknowledgments Schneider Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Republication of SEVD-2026-013-01 Legal Notice and Terms of Use