Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Foxboro DCS Control Software on Foxboro DCS workstations and servers. Control Core Services and all runtime software, like FCPs, FDCs, and FBMs, are not affected. The EcoStruxure Foxboro DCS ([https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/)) product is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediation provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation. The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected: EcoStruxure Foxboro DCS vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric EcoStruxure Foxboro DCS Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-1286 A deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. View CVE Details Affected Products Schneider Electric EcoStruxure Foxboro DCS Vendor: Schneider Electric Product Version: EcoStruxure Foxboro DCS versions prior to CS8.1 Product Status: fixed, known_affected Remediations Vendor fix Version CS 8.1 of EcoStruxure Foxboro DCS includes a fix for this vulnerability and is available through [https://buyautomation.se.com/](https://buyautomation.se.com/) CS 8.1 requires FX-V3 licenses, standard upgrade procedures apply. A reboot is required for workstations and servers. Depending on the existing system version, online upgrade without production interruption might be possible. Schneider Electric recommends you work with your local field service representative or technical service consultant for further information. https://buyautomation.se.com/ Mitigation If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The vulnerability is attacked with manipulated data from external sources to the DCS computers. Examples for these are: * Configuration taglists * DirectAccess Scripts * Any partial or full Galaxy backups * Library files * Code snippets * ASCII files of any sort * Generally, any file getting from outside the DCS computer on a DCS computer. Only use data from trusted sources, check for correct file name endings on data files, check for reasonable file sizes for any files coming to the system, and check structured data for any fields or columns which might be unexpected. Check for unusual manipulations of data within data files and reject files containing unexpected data or structures. Use secure communication channels and encrypt communications when communicating outside the site network. Avoid and ban removable media (e.g. USB sticks or drives) Minimize count of users with engineering or administrative rights to DCS computers and ensure all interactions on DCS computers are executed with minimal user access rights. Consequently, isolating Foxboro DCS computers will help minimizing the risk of this vulnerability being exploited. Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-13 2 Updated remediation and mitigations section. 2026-03-24 3 Initial CISA Republication of Schneider Electric Security Notification SEVD-2026-069-03 Legal Notice and Terms of Use

Grassroots DICOM (GDCM)
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to send a specially crafted file, and when parsed, could result in a denial-of-service condition. The following versions of Grassroots DICOM (GDCM) are affected: Grassroots DICOM (GDCM) 3.2.2 (CVE-2026-3650) CVSS Vendor Equipment Vulnerabilities v3 7.5 Grassroots Grassroots DICOM (GDCM) Missing Release of Memory after Effective Lifetime Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-3650 A memory leak exists in the Grassroots DICOM library (GDCM). The bug occurs when parsing malformed DICOM files with non-standard VR types in file meta information. The vulnerability leads to vast memory allocations and resource depletion, triggering a denial-of-service condition. A maliciously crafted file can fill the heap in a single read operation without properly releasing it. View CVE Details Affected Products Grassroots DICOM (GDCM) Vendor: Grassroots Product Version: Grassroots Grassroots DICOM (GDCM): 3.2.2 Product Status: known_affected Remediations Mitigation The maintainer of Grassroots DICOM (GDCM) has not responded to requests to work with CISA to mitigate this vulnerability. For update information refer to the software page on SourceForge. Mitigation https://sourceforge.net/projects/gdcm/. https://sourceforge.net/projects/gdcm/ Relevant CWE: CWE-401 Missing Release of Memory after Effective Lifetime Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Volodymyr Bihunenko, Mykyta Mudryi, and Markiian Chaklosh of ARIMLABS reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Publication. Legal Notice and Terms of Use

AI in the SOC: What Could Go Wrong?
GénéralDark Readingil y a 6 jours

Two cybersecurity leaders tested out AI in their respective SOCs for six months — and here's what they learned.

Trivy Supply Chain Attack Targets CI/CD Secrets
Vulnérabilités & PatchesDark Readingil y a 6 jours

A threat actor used the open source security tool to deploy an infostealer into CI/CD workflows and steal cloud credentials, SSH keys, tokens, and other sensitive secrets.

Ransomware's New Era: Moving at AI Speed
Gouvernance & RégulationDark Readingil y a 6 jours

Threat actors bypass security tools and use AI to launch faster ransomware attacks that exploit valid credentials and target data.

CISOs Debate Human Role in AI-Powered Security
Gouvernance & RégulationDark Readingil y a 6 jours

The idea of a "human in the loop" in AI deployment was challenged during a security executive panel at the RSAC 2026 Conference this week.

Denver’s crosswalks hacked to broadcast anti-Trump messages
GénéralGraham Cluleyil y a 9 jours

Pedestrians crossing a street in Denver, Colorado, got rather more than they bargained for last weekend, when the audio signals at two crosswalks began broadcasting a political message alongside their usual walking instructions. Read more in my article on the Hot for Security blog.

CISA Adds Five Known Exploited Vulnerabilities to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 9 jours

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-31277 Apple Multiple Products Buffer Overflow Vulnerability CVE-2025-32432 Craft CMS Code Injection Vulnerability CVE-2025-43510 Apple Multiple Products Improper Locking Vulnerability CVE-2025-43520 Apple Multiple Products Classic Buffer Overflow Vulnerability CVE-2025-54068 Laravel Livewire Code Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Russian Intelligence Services Target Commercial Messaging Application Accounts
Threat IntelligenceCISA Advisoriesil y a 9 jours

CISA and the Federal Bureau of Investigation released a Public Service Announcement (PSA) warning about ongoing phishing campaigns by cyber actors associated with the Russian Intelligence Services targeting commercial messaging applications (CMAs). These campaigns aim to bypass encryption to compromise to individual user accounts with targets including current and former U.S. government officials, military personnel, political figures, and journalists. Evidence shows that cyber actors have been able to compromise individual CMA accounts, but not encryption of the applications themselves. The actors’ global campaigns have resulted in unauthorized access to thousands of individual CMA accounts to view the victims’ messages and contact lists, send messages, and conduct additional phishing against other CMA accounts. CISA and FBI urge CMA users to review the PSA, follow recommended cybersecurity practices, and remain vigilant for suspicious activity.

LeakNet ransomware: what you need to know
Malware & RansomwareGraham Cluleyil y a 9 jours

A ransomware gang that claims to be a group of "investigative journalists"? Meet LeakNet - the group using fake CAPTCHA pages to trick employees into hacking themselves. Read more in my article on the Fortra blog.

Post-Quantum Web Could be Safer, Faster
Threat IntelligenceDark Readingil y a 10 jours

Major providers are testing a quantum-safe version of HTTPS that shrinks certificates to one-tenth their previous size, decreasing latency and adding transparency.

Schneider Electric EcoStruxure PME and EPO
Gouvernance & RégulationCISA Advisoriesil y a 10 jours

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Power Monitoring Expert (PME) and EcoStruxure Power Operation (EPO) products. EcoStruxure Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure Power Operation (EPO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system. The following versions of Schneider Electric EcoStruxure PME and EPO are affected: EcoStruxure Power Monitoring Expert (PME) 2022 <=2022 EcoStruxure Power Monitoring Expert (PME) 2023 EcoStruxure Power Monitoring Expert (PME) 2023_R2 EcoStruxure Power Monitoring Expert (PME) 2024 EcoStruxure Power Monitoring Expert (PME) 2024_R2 EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module <=2022 EcoStruxure Power Operation (EPO) Advanced Reporting and Dashboards Module 2024 EcoStruxure Power Monitoring Expert (PME) 2023_R2_Hotfix_282807 EcoStruxure Power Monitoring Expert (PME) 2024_R2_Hotfix_279338__2024R2 CVSS Vendor Equipment Vulnerabilities v3 7.8 Schneider Electric Schneider Electric EcoStruxure PME and EPO Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Healthcare and Public Health, Information Technology, Critical Manufacturing, Commercial Facilities, Energy, Transportation Systems, Government Services and Facilities, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-11739 A deserialization of untrusted data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization. View CVE Details Affected Products Schneider Electric EcoStruxure PME and EPO Vendor: Schneider Electric Product Version: EcoStruxure Power Monitoring Expert (PME) Version 2022 and prior, EcoStruxure Power Monitoring Expert (PME) Version 2023, EcoStruxure Power Monitoring Expert (PME) Version 2023 R2, EcoStruxure Power Monitoring Expert (PME) Version 2024, EcoStruxure Power Monitoring Expert (PME) Version 2024 R2, EcoStruxure Power Operation (EPO) 2022 Advanced Reporting and Dashboards Module Version 2022 and prior, EcoStruxure Power Operation (EPO) 2024 with Advanced Reporting and Dashboards Module Version 2024 Product Status: fixed, known_affected Remediations Vendor fix Hotfix_279338_Release_2024R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this hotfix. No reboot required. Vendor fix Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2024 R3. Contact Schneider Electric’s Customer Care Center for assistance. Vendor fix Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this hotfix. No reboot required. Vendor fix Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for assistance. Vendor fix Customers should upgrade to EcoStruxure Power Monitoring Expert (PME) 2023 R2. Once upgraded, Hotfix_282807 - for 2023R2 is available for EcoStruxure Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for assistance. No fix planned EcoStruxure Power Monitoring Expert (PME) 2022 version has reached its end of life and is no longer supported. • Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm • Ensure PME is running in an isolated network • Deploy and configure the Windows firewall to limit access to appropriate network segments• Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm No fix planned EcoStruxure Power Operation (EPO) 2022 version and EcoStruxure Power Monitoring Expert (PME) 2022 has reached its end of life and is no longer supported. • Ensure your deployment of PME has followed the cybersecurity hardening guidelines provided with the product. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm • Ensure PME is running in an isolated network • Deploy and configure the Windows firewall to limit access to appropriate network segments• Enforce complex password policies.o Review Server Access Permissions o Conduct an audit of all Windows-authenticated users who currently have access to PME. Repeat this audit of your system periodically. o Identify all accounts with access rights, especially those with elevated privileges or remote access. o Limit access to essential users only.o Revoke access for any user accounts that are not critical for system functionality or daily operations.o Apply the principle of least privilege to ensure users have only the access necessary for their role(s). Customers should also consider upgrading to the latest product offering EcoStruxure Power Monitoring Expert (PME) 2024 R3 to resolve this issue. https://product-help.schneider-electric.com/EcoStruxure/Power-Monitoring-Expert-2024/content/2_planning/cybersecurity/cyber-planningrecactions.htm Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Note EcoStruxure Power Operation 2022 with Advanced Reporting AND EcoStruxure Power Operation 2024 with Advanced Reporting utilizes EcoStruxure Power Monitoring Expert. You must update EcoStruxure Power Monitoring Expert separately from EcoStruxure Power Operation and apply the appropriate update for Power Monitoring Expert as described above. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-06 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-19 2 Initial CISA Republication of Schneider Electric SEVD-2026-069-06 advisory Legal Notice and Terms of Use

Schneider Electric Modicon M241, M251, and M262
Gouvernance & RégulationCISA Advisoriesil y a 10 jours

View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the product. The following versions of Schneider Electric Modicon M241, M251, and M262 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon M262 versions prior to 5.4.10.12 Modicon_Controller_M262 CVSS Vendor Equipment Vulnerabilities v3 5.3 Schneider Electric Schneider Electric Modicon M241, M251, and M262 Improper Resource Shutdown or Release Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13901 CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. View CVE Details Affected Products Schneider Electric Modicon M241, M251, and M262 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon M262 versions prior to 5.4.10.12: Modicon_Controller_M262 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M262 Firmware version 5.4.10.12 delivered with EcoStruxure™ Machine Expert v2.5 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M262 to the latest Firmware and perform reboot. For instructions refer to Modicon M262 Logic/Motion Controller, Programming Guide: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-01 Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf. Improper Resource Shutdown or Release vulnerability in Multiple Products - SEVD-2026-069-01 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-01.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-01.pdf Mitigation All affected products: If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Filter ports and IP through the embedded firewall. Use encrypted communication links. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Relevant CWE: CWE-404 Improper Resource Shutdown or Release Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L Acknowledgments Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-01 Legal Notice and Terms of Use