Flux RSS

— Sources secondaires
115articles RSS
Reinitialiser
Schneider Electric Plant iT/Brewmaxx
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Successful exploitation of these vulnerabilities could risk privilege escalation, which could result in remote code execution. The following versions of Schneider Electric Plant iT/Brewmaxx are affected: Plant iT/Brewmaxx 9.60_and_above (CVE-2025-49844, CVE-2025-46817, CVE-2025-46818, CVE-2025-46819) CVSS Vendor Equipment Vulnerabilities v3 9.9 Schneider Electric Schneider Electric Plant iT/Brewmaxx Use After Free, Integer Overflow or Wraparound, Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Energy, Critical Manufacturing, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-49844 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate the garbage collector, trigger a use-after-free, and potentially lead to remote code execution. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-416 Use After Free Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2025-46817 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to cause an integer overflow and potentially lead to remote code execution View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2025-46818 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 6 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N CVE-2025-46819 The affected product uses Redis, an open-source, in-memory database. Versions 8.2.1 and below allow an authenticated user to use a specially crafted LUA script to read out-of-bound data or crash the server and subsequent denial of service. View CVE Details Affected Products Schneider Electric Plant iT/Brewmaxx Vendor: Schneider Electric Product Version: Schneider Electric Plant iT/Brewmaxx: 9.60_and_above Product Status: known_affected Remediations Mitigation Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploit: Mitigation Install Patch ProLeiT-2025-001 via ProLeiT Support https://www.proleit.com/support/ Mitigation After installing ProLeiT-2025-001, disable the eval commands in Redis on the application server, VisuHub, engineering workstations, and workstations with emergency mode functionality Mitigation Force usage of secure Redis configuration templates in system settings as documented in the patch manual Mitigation Restart all patched servers and workstations Mitigation Schneider Electric strongly recommends the following industry cybersecurity best practices. Mitigation Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Mitigation Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. Mitigation Place all controllers in locked cabinets and never leave them in the "Program" mode. Mitigation Never connect programming software to any network other than the network intended for that device. Mitigation Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. Mitigation Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. Mitigation Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. Mitigation When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. Mitigation For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. https://www.se.com/us/en/download/document/7EN52-0390/ Vendor fix For more information, see Schneider Electric security notification "SEVD-2026-013-01 Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx" https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-013-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-013-01.pdf Relevant CWE: CWE-190 Integer Overflow or Wraparound Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.3 MEDIUM CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:H Acknowledgments Schneider Electric reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-24 Date Revision Summary 2026-03-24 1 Initial Republication of SEVD-2026-013-01 Legal Notice and Terms of Use

Ghost Campaign Uses 7 npm Packages to Steal Crypto Wallets and Credentials
Threat IntelligenceThe Hacker Newsil y a 5 jours

Cybersecurity researchers have uncovered a new set of malicious npm packages that are designed to steal cryptocurrency wallets and sensitive data. The activity is being tracked by ReversingLabs as the Ghost campaign. The list of identified packages, all published by a user named mikilanjillo, is below - react-performance-suite react-state-optimizer-core react-fast-utilsa ai-fast-auto-trader

Schneider Electric EcoStruxure Foxboro DCS
Gouvernance & RégulationCISA Advisoriesil y a 5 jours

View CSAF Summary Schneider Electric is aware of a vulnerability in its EcoStruxure Foxboro DCS Control Software on Foxboro DCS workstations and servers. Control Core Services and all runtime software, like FCPs, FDCs, and FBMs, are not affected. The EcoStruxure Foxboro DCS ([https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/)) product is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediation provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation. The following versions of Schneider Electric EcoStruxure Foxboro DCS are affected: EcoStruxure Foxboro DCS vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric EcoStruxure Foxboro DCS Deserialization of Untrusted Data Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-1286 A deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file. View CVE Details Affected Products Schneider Electric EcoStruxure Foxboro DCS Vendor: Schneider Electric Product Version: EcoStruxure Foxboro DCS versions prior to CS8.1 Product Status: fixed, known_affected Remediations Vendor fix Version CS 8.1 of EcoStruxure Foxboro DCS includes a fix for this vulnerability and is available through [https://buyautomation.se.com/](https://buyautomation.se.com/) CS 8.1 requires FX-V3 licenses, standard upgrade procedures apply. A reboot is required for workstations and servers. Depending on the existing system version, online upgrade without production interruption might be possible. Schneider Electric recommends you work with your local field service representative or technical service consultant for further information. https://buyautomation.se.com/ Mitigation If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: The vulnerability is attacked with manipulated data from external sources to the DCS computers. Examples for these are: * Configuration taglists * DirectAccess Scripts * Any partial or full Galaxy backups * Library files * Code snippets * ASCII files of any sort * Generally, any file getting from outside the DCS computer on a DCS computer. Only use data from trusted sources, check for correct file name endings on data files, check for reasonable file sizes for any files coming to the system, and check structured data for any fields or columns which might be unexpected. Check for unusual manipulations of data within data files and reject files containing unexpected data or structures. Use secure communication channels and encrypt communications when communicating outside the site network. Avoid and ban removable media (e.g. USB sticks or drives) Minimize count of users with engineering or administrative rights to DCS computers and ensure all interactions on DCS computers are executed with minimal user access rights. Consequently, isolating Foxboro DCS computers will help minimizing the risk of this vulnerability being exploited. Relevant CWE: CWE-502 Deserialization of Untrusted Data Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in sustainability and efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric SEVD-2026-069-03 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-13 2 Updated remediation and mitigations section. 2026-03-24 3 Initial CISA Republication of Schneider Electric Security Notification SEVD-2026-069-03 Legal Notice and Terms of Use

TeamPCP Hacks Checkmarx GitHub Actions Using Stolen CI Credentials
Malware & RansomwareThe Hacker Newsil y a 5 jours

Two more GitHub Actions workflows have become the latest to be compromised by credential-stealing malware by a threat actor known as TeamPCP, the cloud-native cybercriminal operation also behind the Trivy supply chain attack. The workflows, both maintained by the supply chain security company Checkmarx, are listed below - checkmarx/ast-github-action checkmarx/kics-github-action Cloud security

U.S. Sentences Russian Hacker to 6.75 Years for Role in $9M Ransomware Damage
Malware & RansomwareThe Hacker Newsil y a 6 jours

A 26-year-old Russian citizen has been sentenced in the U.S. to 6.75 years (81 months) in prison for his role in assisting major cybercrime groups, including the Yanluowang ransomware crew, in conducting numerous attacks against U.S. companies and other organizations. According to the U.S. Department of Justice (DoJ), Aleksei Olegovich Volkov facilitated dozens of ransomware attacks across the

Citrix Urges Patching Critical NetScaler Flaw Allowing Unauthenticated Data Leaks
Gouvernance & RégulationThe Hacker Newsil y a 6 jours

Citrix has released security updates to address two vulnerabilities in NetScaler ADC and NetScaler Gateway, including a critical flaw that could be exploited to leak sensitive data from the application. The vulnerabilities are listed below - CVE-2026-3055 (CVSS score: 9.3) - Insufficient input validation leading to memory overread CVE-2026-4368 (CVSS score: 7.7) - Race condition leading to user

North Korean Hackers Abuse VS Code Auto-Run Tasks to Deploy StoatWaffle Malware
Malware & RansomwareThe Hacker Newsil y a 6 jours

The North Korean threat actors behind the Contagious Interview campaign, also tracked as WaterPlum, have been attributed to a malware family tracked as StoatWaffle that's distributed via malicious Microsoft Visual Studio Code (VS Code) projects. The use of VS Code "tasks.json" to distribute malware is a relatively new tactic adopted by the threat actor since December 2025, with the attacks

⚡ Weekly Recap: CI/CD Backdoor, FBI Buys Location Data, WhatsApp Ditches Numbers & More
Gouvernance & RégulationThe Hacker Newsil y a 6 jours

Another week, another reminder that the internet is still a mess. Systems people thought were secure are being broken in simple ways, showing many still ignore basic advisories. This edition covers a mix of issues: supply chain attacks hitting CI/CD setups, long-abused IoT devices being shut down, and exploits moving quickly from disclosure to real attacks. There are also new malware tricks

We Found Eight Attack Vectors Inside AWS Bedrock. Here's What Attackers Can Do with Them
Vulnérabilités & PatchesThe Hacker Newsil y a 6 jours

AWS Bedrock is Amazon's platform for building AI-powered applications. It gives developers access to foundation models and the tools to connect those models directly to enterprise data and systems. That connectivity is what makes it powerful – but it’s also what makes Bedrock a target. When an AI agent can query your Salesforce instance, trigger a Lambda function, or pull from a SharePoint

Microsoft Warns IRS Phishing Hits 29,000 Users, Deploys RMM Malware
Gouvernance & RégulationThe Hacker Newsil y a 6 jours

Microsoft has warned of fresh campaigns that are capitalizing on the upcoming tax season in the U.S. to harvest credentials and deliver malware. The email campaigns take advantage of the urgency and time-sensitive nature of emails to send phishing messages masquerading as refund notices, payroll forms, filing reminders, and requests from tax professionals to deceive recipients into opening

Trivy Hack Spreads Infostealer via Docker, Triggers Worm and Kubernetes Wiper
Malware & RansomwareThe Hacker Newsil y a 6 jours

Cybersecurity researchers have uncovered malicious artifacts distributed via Docker Hub following the Trivy supply chain attack, highlighting the widening blast radius across developer environments. The last known clean release of Trivy on Docker Hub is 0.69.3. The malicious versions 0.69.4, 0.69.5, and 0.69.6 have since been removed from the container image library. "New image tags 0.69.5 and

Hackers Exploit CVE-2025-32975 (CVSS 10.0) to Hijack Unpatched Quest KACE SMA Systems
Gouvernance & RégulationThe Hacker Newsil y a 7 jours

Threat actors are suspected to be exploiting a maximum-severity security flaw impacting Quest KACE Systems Management Appliance (SMA), according to Arctic Wolf. The cybersecurity company said it observed malicious activity starting the week of March 9, 2026, in customer environments that's consistent with the exploitation of CVE-2025-32975 on unpatched SMA systems exposed to the internet. It's

FBI Warns Russian Hackers Target Signal, WhatsApp in Mass Phishing Attacks
Threat IntelligenceThe Hacker Newsil y a 8 jours

Threat actors affiliated with Russian Intelligence Services are conducting phishing campaigns to compromise commercial messaging applications (CMAs) like WhatsApp and Signal to seize control of accounts belonging to individuals with high intelligence value, the U.S. Cybersecurity and Infrastructure Security Agency (CISA) and Federal Bureau of Investigation (FBI) said Friday. "The campaign

Oracle Patches Critical CVE-2026-21992 Enabling Unauthenticated RCE in Identity Manager
Gouvernance & RégulationThe Hacker Newsil y a 8 jours

Oracle has released security updates to address a critical security flaw impacting Identity Manager and Web Services Manager that could be exploited to achieve remote code execution. The vulnerability, tracked as CVE-2026-21992, carries a CVSS score of 9.8 out of a maximum of 10.0. "This vulnerability is remotely exploitable without authentication," Oracle said in an advisory. "If successfully

Trivy Supply Chain Attack Triggers Self-Spreading CanisterWorm Across 47 npm Packages
Malware & RansomwareThe Hacker Newsil y a 8 jours

The threat actors behind the supply chain attack targeting the popular Trivy scanner are suspected to be conducting follow-on attacks that have led to the compromise of a large number of npm packages with a previously undocumented self-propagating worm dubbed CanisterWorm. The name is a reference to the fact that the malware uses an ICP canister, which denotes a tamperproof smart contract on

CISA Flags Apple, Craft CMS, Laravel Bugs in KEV, Orders Patching by April 3, 2026
Gouvernance & RégulationThe Hacker Newsil y a 8 jours

The U.S. Cybersecurity and Infrastructure Security Agency (CISA) on Friday added five security flaws impacting Apple, Craft CMS, and Laravel Livewire to its Known Exploited Vulnerabilities (KEV) catalog, urging federal agencies to patch them by April 3, 2026. The vulnerabilities that have come under exploitation are listed below - CVE-2025-31277 (CVSS score: 8.8) - A vulnerability in Apple

Trivy Security Scanner GitHub Actions Breached, 75 Tags Hijacked to Steal CI/CD Secrets
Vulnérabilités & PatchesThe Hacker Newsil y a 9 jours

Trivy, a popular open-source vulnerability scanner maintained by Aqua Security, was compromised a second time within the span of a month to deliver malware capable of stealing sensitive CI/CD secrets. The latest incident impacted GitHub Actions "aquasecurity/trivy-action" and "aquasecurity/setup-trivy," which are used to scan Docker container images for vulnerabilities and set up GitHub Actions

Critical Langflow Flaw CVE-2026-33017 Triggers Attacks within 20 Hours of Disclosure
Gouvernance & RégulationThe Hacker Newsil y a 9 jours

A critical security flaw impacting Langflow has come under active exploitation within 20 hours of public disclosure, highlighting the speed at which threat actors weaponize newly published vulnerabilities. The security defect, tracked as CVE-2026-33017 (CVSS score: 9.3), is a case of missing authentication combined with code injection that could result in remote code execution. "The POST /api/v1

Russian Intelligence Services Target Commercial Messaging Application Accounts
Threat IntelligenceCISA Advisoriesil y a 9 jours

CISA and the Federal Bureau of Investigation released a Public Service Announcement (PSA) warning about ongoing phishing campaigns by cyber actors associated with the Russian Intelligence Services targeting commercial messaging applications (CMAs). These campaigns aim to bypass encryption to compromise to individual user accounts with targets including current and former U.S. government officials, military personnel, political figures, and journalists. Evidence shows that cyber actors have been able to compromise individual CMA accounts, but not encryption of the applications themselves. The actors’ global campaigns have resulted in unauthorized access to thousands of individual CMA accounts to view the victims’ messages and contact lists, send messages, and conduct additional phishing against other CMA accounts. CISA and FBI urge CMA users to review the PSA, follow recommended cybersecurity practices, and remain vigilant for suspicious activity.

CISA Adds Five Known Exploited Vulnerabilities to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 9 jours

CISA has added five new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-31277 Apple Multiple Products Buffer Overflow Vulnerability CVE-2025-32432 Craft CMS Code Injection Vulnerability CVE-2025-43510 Apple Multiple Products Improper Locking Vulnerability CVE-2025-43520 Apple Multiple Products Classic Buffer Overflow Vulnerability CVE-2025-54068 Laravel Livewire Code Injection Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.