CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20131 Cisco Secure Firewall Management Center (FMC) Software and Cisco Security Cloud Control (SCC) Firewall Management Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
Flux RSS
— Sources secondairesView CSAF Summary Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser. The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon Controllers M258 all firmware versions Modicon_Controllers_M258 Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058 CVSS Vendor Equipment Vulnerabilities v3 5.4 Schneider Electric Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. View CVE Details Affected Products Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000003059/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/us/en/download/document/EIO0000003089/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N Acknowledgments Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02 Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of CTEK Chargeportal are affected: Chargeportal vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 CTEK CTEK Chargeportal Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities Expand All + CVE-2026-25192 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-31904 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-27649 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-28204 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products CTEK Chargeportal Vendor: CTEK Product Version: CTEK Chargeportal: vers:all/* Product Status: known_affected Remediations Mitigation CTEK will be sunsetting this product in April 2026. Please contact CTEK for more information https://www.ctek.com/support. https://www.ctek.com/support Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine, Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Publication Legal Notice and Terms of Use
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of IGL-Technologies eParking.fi are affected: eParking.fi vers:all/* CVSS Vendor Equipment Vulnerabilities v3 9.4 IGL-Technologies IGL-Technologies eParking.fi Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Finland Vulnerabilities Expand All + CVE-2026-29796 WebSocket endpoints lack proper authentication mechanisms, enabling attackers to perform unauthorized station impersonation and manipulate data sent to the backend. An unauthenticated attacker can connect to the OCPP WebSocket endpoint using a known or discovered charging station identifier, then issue or receive OCPP commands as a legitimate charger. Given that no authentication is required, this can lead to privilege escalation, unauthorized control of charging infrastructure, and corruption of charging network data reported to the backend. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.4 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L CVE-2026-31903 The WebSocket Application Programming Interface lacks restrictions on the number of authentication requests. This absence of rate limiting may allow an attacker to conduct denial-of-service attacks by suppressing or mis-routing legitimate charger telemetry, or conduct brute-force attacks to gain unauthorized access. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-307 Improper Restriction of Excessive Authentication Attempts Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-32663 The WebSocket backend uses charging station identifiers to uniquely associate sessions but allows multiple endpoints to connect using the same session identifier. This implementation results in predictable session identifiers and enables session hijacking or shadowing, where the most recent connection displaces the legitimate charging station and receives backend commands intended for that station. This vulnerability may allow unauthorized users to authenticate as other users or enable a malicious actor to cause a denial-of-service condition by overwhelming the backend with valid session requests. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-613 Insufficient Session Expiration Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.3 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L CVE-2026-31926 Charging station authentication identifiers are publicly accessible via web-based mapping platforms. View CVE Details Affected Products IGL-Technologies eParking.fi Vendor: IGL-Technologies Product Version: IGL-Technologies eParking.fi: vers:all/* Product Status: known_affected Remediations Mitigation IGL-Technologies has updated eParking's OCPP servers to reduce the risks posed by the vulnerability. These updates implemented the following security controls: 1) Enforce modern security profiles and stronger authentication. 2) Device‑level whitelisting was implemented to ensure that only authorized charging units can connect. 3) Rate‑limiting controls prevent excessive requests and reduces DoS risk. 4) Enhanced automated monitoring and alerting to detection abnormal network activity. Mitigation Devices using the encrypted deployment of eParking's OCPP servers or IGL-Technologies proprietary eTolppa protocol are not impacted by these vulnerabilities. Mitigation To prevent this in the future IGL-Technologies will continue vulnerability monitoring under their ISO 27001:2022 security program and tighten security requirements for future third‑party OCPP hardware approvals. Mitigation For more information please contact the IGL-Technologies security team at this email address: security@igl.fi. mailto:security@igl.fi Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N Acknowledgments Khaled Sarieddine and Mohammad Ali Sayed reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Publication Legal Notice and Terms of Use
The European Union – the media freedom hub marsrgi Thu, 03/19/2026 - 08:58 Opening: 16 April 2026 Closing: 28 May 2026 The overall goal of this preparatory action is to continue the activities of the ongoing Free Media Hub EAST project, i.e. to sustain and improve existing financial and other kinds of support to exiled independent media from Russia, Belarus, as well as media from Ukraine that has relocated in the EU, and to foster the coordination and consolidation of a pan-European platform or network of media hubs to promote the preservation of a pluralistic media environment. GettyImages © Mihajlo Maricic Main link https://ec.europa.eu/info/funding-tenders/opportunities/portal/screen/opportuni… Related topics Media and democracy Media freedom and pluralism International relations Funding for Digital Actions to Support Ukraine Democracy in the digital age {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
Where are you? What are you working on? Why are you doing that? Identity access and management platform Okta announced the general availability of its Okta for AI Agents, which will give customers the ability to do three things: locate agents, see what they’re doing, and shut them down if need be.…
Darksword is the second iOS exploit chain in a month A new exploit kit targeting iPhone users and stealing their sensitive data is being abused by "multiple" spyware vendors and suspected nation-state goons, security researchers said on Wednesday.…
Interlock's post-exploit toolkit exposed Ransomware criminals exploited CVE-2026-20131, a maximum-severity bug in Cisco Secure Firewall Management Center software, as a zero-day vulnerability more than a month before Cisco patched the hole, according to Amazon security boss CJ Moses.…
Researchers map full org chart of the scam from dodgy recruiters to helpful Western collaborators Researchers at IBM X‑Force and Flare Research have uncovered data that sheds light on how North Korea's fake IT worker schemes operate and infiltrate companies in order to funnel money back to the regime and steal sensitive information.…
No 1 Space Operations Squadron will get a persistent stare capability The Ministry of Defence (MoD) plans to spend £17.5 million on a remotely-operated satellite monitoring facility in Cyprus, partly to protect the UK's secure communications system Skynet.…
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20963 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.1 To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions. To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft’s newly released best practices for securing Microsoft Intune; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software: Use principles of least privilege when designing administrative roles. Leverage Microsoft Intune’s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations—permissions include what actions the role can take, and what users and devices it can apply that action to. Enforce phishing-resistant multi-factor authentication (MFA) and privileged access hygiene. Use Microsoft Entra ID capabilities (including Conditional Access, MFA, risk signals, and privileged access controls) to block unauthorized access to privileged actions in Microsoft Intune. Configure access policies to require Multi Admin Approval in Microsoft Intune. Set up policies that require a second administrative account’s approval to allow changes to sensitive or high-impact actions (such as device wiping), applications, scripts, RBAC, configurations, etc. Additionally, CISA recommends reviewing the following resources to strengthen defenses against similar malicious cyber activity: Microsoft resources: For recommendations on securing Microsoft Intune, see Best practices for securing Microsoft Intune. For guidance on implementing Multi Admin Approval in Microsoft Intune, see Use Access policies to implement Multi Admin Approval. For recommendations on configuring Microsoft Intune using zero trust principles, see Configure Microsoft Intune for increased security. For guidance on implementing Microsoft Intune RBAC policies, see Role-based access control (RBAC) with Microsoft Intune. For guidance on deploying Privileged Identity Management (PIM) across Microsoft Intune, Entra ID, and other Microsoft software, see Plan a Privileged Identity Management deployment. CISA resources: For guidance on implementing phishing-resistant multifactor authentication (MFA), see Implementing Phishing-Resistant MFA. Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements Microsoft and Stryker contributed to this alert. Notes 1 For updates from Stryker on the incident, see “Customer Updates: Stryker Network Disruption,” Stryker, last modified March 15, 2026, https://www.stryker.com/us/en/about/news/2026/a-message-to-our-customers-03-2026.html.
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-66376 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.
CEF-Digital Info Session: 2026 Calls Anonymous (not verified) Wed, 03/18/2026 - 10:35 26 March 2026 Online Learn more about the calls "Equipment for smart European cable systems" (CEF-DIG-2026-SMART-CABLES) and "Backbone connectivity for Digital Global Gateways" (CEF-DIG-2026-GATEWAYS). GettyImages © Dragon Claws Main link https://hadea.ec.europa.eu/events/cef-digital-info-session-2026-calls-2026-03-2… Related topics Connecting Europe Facility Funding for Digital Related content Press release 17 March 2026 Commission makes available €200 million for submarine cable and digital infrastructure projects The European Commission has opened two new Connecting Europe Facility (CEF) calls worth €200 million for projects in high-capacity networks, including submarine cables. {"service":"share","version":"2.0","color":true,"networks":["x","facebook","linkedin","email","more"]}
Even without a navy, or air power, 'They'll still have the ability to hack' Businesses should expect that Iran will conduct more aggressive cyber-ops as the war escalates, according to security analysts.…
Big Tech donates $12.5 million to get things rolling Half a dozen Big Tech players have together delivered $12.5 million in grants towards a project that aims to help maintainers of open source projects to cope with AI slop bug reports.…
In less polite places, this is called ‘hacking back’ or ‘offensive cyber-ops’ Japan’s government yesterday decided to allow its Self-Defense Force to conduct offensive cyber-operations, starting on October 1st.…
Sell your soul to the orb Sam Altman has cooked up a plan to make his cryptocurrency/identity/eyeball-scanning-orb venture more useful by – you guessed it – adding agentic AI to the mix. Now the technology behind it will be used to identify the human behind bots.…
State-sponsored attackers joined by Chinese snoops and hackers-for-hire in latest round of economic penalties The Council of the European Union sanctioned Emennet Pasargad on Monday, a company used as a front for a series of Iranian cyberattacks.…
View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens has released a new version for SICAM SIAPP SDK and recommends to update to the latest version. The following versions of Siemens SICAM SIAPP SDK are affected: SICAM SIAPP SDK vers:intdot/<2.1.7 CVSS Vendor Equipment Vulnerabilities v3 7.4 Siemens Siemens SICAM SIAPP SDK Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25569 An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25570 The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25571 The SICAM SIAPP SDK client component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25572 The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25573 The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25605 The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. Maxime Rossi Bellom of Secmate reported these vulnerabilities to Siemens. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-903736 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-17 2 Initial CISA Republication of Siemens ProductCERT SSA-903736 advisory Legal Notice and Terms of Use