Schneider Electric EcoStruxure Data Center Expert
Gouvernance & RégulationCISA Advisoriesil y a 12 jours

View CSAF Summary Schneider Electric is aware of a hard-coded credentials vulnerability in its EcoStruxure IT Data Center Expert (DCE) product that requires administrator credentials and enabling a feature (SOCKS Proxy) that is off by default. The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes, and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure, and remote compromise of the offer which could result in disruption of operations and access to system data. The following versions of Schneider Electric EcoStruxure Data Center Expert are affected: EcoStruxure IT Data Center Expert vers:intdot/<=9.0 EcoStruxure IT Data Center Expert 9.1 CVSS Vendor Equipment Vulnerabilities v3 7.2 Schneider Electric Schneider Electric EcoStruxure Data Center Expert Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Commercial Facilities, Energy, Food and Agriculture, Government Services and Facilities, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13957 A hard-coded credentials vulnerability exists that could lead to information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. View CVE Details Affected Products Schneider Electric EcoStruxure Data Center Expert Vendor: Schneider Electric Product Version: EcoStruxure IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) v9.0 and prior Product Status: fixed, known_affected Remediations Vendor fix v9.1 of EcoStruxure IT Data Center Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/en/product-range/61851-ecostruxure-it-data-center-expert/#software-and-firmware Mitigation If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: • Harden the DCE instance according to the cybersecurity best practices documented in the EcoStruxure IT Data Center Expert Security Handbook • Ensure the SOCKS Proxy is disabled as in the default configuration. Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert PDF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-05.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-05 Use of Hard-coded Credentials vulnerability in EcoStruxure IT Data Center Expert CSAF Version https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-05.json Relevant CWE: CWE-798 Use of Hard-coded Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.2 HIGH CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H Acknowledgments hassan ali of TrendAI Zero Day Initiative reported this vulnerability to Schneider Electric General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices: * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-069-05 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric SEVD-2026-069-05 advisory Legal Notice and Terms of Use

Schneider Electric SCADAPack and RemoteConnect
Gouvernance & RégulationCISA Advisoriesil y a 12 jours

View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack™ x70 RTU products. The SCADAPack™ 47xi, SCADAPack™ 47x and SCADAPack™ 57x product are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the remediations provided below may risk unauthorized access to your RTU, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. The following versions of Schneider Electric SCADAPack and RemoteConnect are affected: SCADAPack™ vers:generic/ SCADAPack™ firmware vers:intdot/<9.12.2, 9.12.2, vers:intdot/<9.12.2, 9.12.2 () RemoteConnect vers:generic/ CVSS Vendor Equipment Vulnerabilities v3 9.8 Schneider Electric Schneider Electric SCADAPack and RemoteConnect Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-0667 CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol. View CVE Details Affected Products Schneider Electric SCADAPack and RemoteConnect Vendor: Schneider Electric Product Version: SCADAPack™ 57x All Versions, RemoteConnect Versions prior to R3.4.2 Product Status: fixed, known_affected Remediations Vendor fix Version R3.4.2 (Firmware version 9.12.2) of SCADAPack™ 47x and SCADAPack™ 47xi includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Vendor fix Version R3.4.2 of RemoteConnect includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit: • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services • Disable the logic debug service. Mitigation Follow the information according to SCADAPack™ Security Guidelines in section 8.3 Secured Communication. Also, apply the following standard practices to reduce the risk of exploit • Setup network segmentation and implement the RTU firewall service to block all unauthorized access to services. • Disable the logic debug service. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H Acknowledgments Schneider Electric CPCERT reported this vulnerability to CISA. General Security Recommendations We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document. For More Information This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric's products, visit the company's cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp LEGAL DISCLAIMER THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION About Schneider Electric Schneider's purpose is to create Impact by empowering all to make the most of our energy and resources, bridging progress and sustainability for all. We call this Life Is On. Our mission is to be the trusted partner in Sustainability and Efficiency. We are a global industrial technology leader bringing world-leading expertise in electrification, automation and digitization to smart industries, resilient infrastructure, future-proof data centers, intelligent buildings, and intuitive homes. Anchored by our deep domain expertise, we provide integrated end-to-end lifecycle AI enabled Industrial IoT solutions with connected products, automation, software and services, delivering digital twins to enable profitable growth for our customers. We are a people company with an ecosystem of 150,000 colleagues and more than a million partners operating in over 100 countries to ensure proximity to our customers and stakeholders. We embrace diversity and inclusion in everything we do, guided by our meaningful purpose of a sustainable future for all. www.se.com Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Schneider Electric CPCERT SEVD-2026-041-01 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Schneider Electric CPCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-02-10 Date Revision Summary 2026-02-10 1 Original Release 2026-03-17 2 Initial CISA Republication of Schneider Electric CPCERT SEVD-2026-041-01 advisory Legal Notice and Terms of Use

Siemens SICAM SIAPP SDK
Gouvernance & RégulationCISA Advisoriesil y a 12 jours

View CSAF Summary The SICAM SIAPP SDK contains multiple vulnerabilities that could allow an attacker to disrupt the customer-developed SIAPP or its simulation environment. Potential impacts include denial of service within the SIAPP, corruption of SIAPP data, or exploit the simulation environment. These vulnerabilities are only exploitable if the API is used improperly or hardening measures are not applied. Siemens has released a new version for SICAM SIAPP SDK and recommends to update to the latest version. The following versions of Siemens SICAM SIAPP SDK are affected: SICAM SIAPP SDK vers:intdot/<2.1.7 CVSS Vendor Equipment Vulnerabilities v3 7.4 Siemens Siemens SICAM SIAPP SDK Out-of-bounds Write, Stack-based Buffer Overflow, Improper Handling of Length Parameter Inconsistency, External Control of File Name or Path Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-25569 An out-of-bounds write vulnerability exists in SICAM SIAPP SDK. This could allow an attacker to write data beyond the intended buffer, potentially leading to denial of service, or arbitrary code execution. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25570 The SICAM SIAPP SDK does not perform checks on input values potentially resulting in stack overflow. This could allow an attacker to perform code execution and denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-121 Stack-based Buffer Overflow Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25571 The SICAM SIAPP SDK client component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25572 The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-130 Improper Handling of Length Parameter Inconsistency Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.1 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H CVE-2026-25573 The affected application builds shell commands with caller-provided strings and executes them. An attacker could influence the executed command, potentially resulting in command injection and full system compromise. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.4 HIGH CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2026-25605 The affected application performs file deletion without properly validating the file path or target. An attacker could delete files or sockets that the affected process has permission to remove, potentially resulting in denial of service or service disruption. View CVE Details Affected Products Siemens SICAM SIAPP SDK Vendor: Siemens Product Version: SICAM SIAPP SDK Product Status: known_affected Remediations Vendor fix Update to V2.1.7 or later Relevant CWE: CWE-73 External Control of File Name or Path Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.7 MEDIUM CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. Maxime Rossi Bellom of Secmate reported these vulnerabilities to Siemens. General Recommendations Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid's reliability can thus be minimized by virtue of the grid design. Siemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. As a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment. Recommended security guidelines can be found at: https://www.siemens.com/gridsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-903736 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Publication Date 2026-03-17 2 Initial CISA Republication of Siemens ProductCERT SSA-903736 advisory Legal Notice and Terms of Use

South Korean Police Accidentally Post Cryptocurrency Wallet Password
Gouvernance & RégulationSchneier on Securityil y a 12 jours

An expensive mistake: Someone jumped at the opportunity to steal $4.4 million in crypto assets after South Korea’s National Tax Service exposed publicly the mnemonic recovery phrase of a seized cryptocurrency wallet. The funds were stored in a Ledger cold wallet seized in law enforcement raids at 124 high-value tax evaders that resulted in confiscating digital assets worth 8.1 billion won (currently approximately $5.6 million). When announcing the success of the operation, the agency released photos of a Ledger device, a popular hardware wallet for crypto storage and management. However, the images also showed a handwritten note of the wallet recovery phrase, which serves as the master key that allows restoring the assets to another device. The authorities failed to redact that info, allowing anyone to transfer into their account the assets in the cold wallet. Reportedly, shortly after the press release was published, 4 million Pre-Retogeum (PRTG) tokens, worth approximately $4.8 million at the time, were transferred out of the confiscated wallet to a new address.

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 13 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-47813 Wing FTP Server Information Disclosure Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Possible New Result in Quantum Factorization
GénéralSchneier on Securityil y a 13 jours

I’m skeptical about—and not qualified to review—this new result in factorization with a quantum computer, but if it’s true it’s a theoretical improvement in the speed of factoring large numbers with a quantum computer.

CISA Adds Two Known Exploited Vulnerabilities to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 16 jours

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-3909 Google Skia Out-of-Bounds Write Vulnerability CVE-2026-3910 Google Chromium V8 Unspecified Vulnerability These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.