Flux RSS

— Sources secondaires
166articles RSS
Reinitialiser
Schneider Electric Modicon Controllers M241, M251, M258, and LMC058
Gouvernance & RégulationCISA Advisoriesil y a 11 jours

View CSAF Summary Successful exploitation of this vulnerability may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser. The following versions of Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 are affected: Modicon M241 versions prior to 5.4.13.12 Modicon_Controller_M241 Modicon M251 versions prior to 5.4.13.12 Modicon_Controller_M251 Modicon Controllers M258 all firmware versions Modicon_Controllers_M258 Modicon Controllers LMC058 all firmware versions Modicon_Controllers_LMC058 CVSS Vendor Equipment Vulnerabilities v3 5.4 Schneider Electric Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim's browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. View CVE Details Affected Products Schneider Electric Modicon Controllers M241, M251, M258, and LMC058 Vendor: Schneider Electric Product Version: Schneider Electric Modicon M241 versions prior to 5.4.13.12: Modicon_Controller_M241, Schneider Electric Modicon M251 versions prior to 5.4.13.12: Modicon_Controller_M251, Schneider Electric Modicon Controllers M258 all firmware versions: Modicon_Controllers_M258, Schneider Electric Modicon Controllers LMC058 all firmware versions: Modicon_Controllers_LMC058 Product Status: known_affected Remediations Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000003059/ Mitigation Schneider Electric has identified the following specific workarounds and mitigations users can apply to reduce risk: Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/EIO0000005500/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/us/en/download/document/EIO0000003089/ Mitigation Modicon Controller M251 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/. On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/. Update Modicon Controller M251 to the latest Firmware and perform reboot. For instructions refer to Modicon M251 Logic Controller, Programming Guide: https://www.se.com/us/en/download/document/EIO0000003089/, https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER. https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER Mitigation If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation Modicon Controllers M258 and Modicon Controllers LMC058: Use controllers and devices only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. Ensure usage of user management and password features. User rights are enabled by default and forced to create a strong password at first use. Deactivate the Webserver after use when not needed. Use encrypted communication links. Setup network segmentation and implement a firewall to block all unauthorized access to ports 80/HTTP and 443/HTTPS. Use VPN (Virtual Private Networks) tunnels if remote access is required. The "Cybersecurity Guidelines for EcoStruxure Machine Expert, Modicon and PacDrive Controllers and Associated Equipment" provide product specific hardening guidelines: https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242. https://download.schneider-electric.com/files?p_enDocType=User+guide&p_File_Name=EIO0000004242.00.pdf&p_Doc_Ref=EIO0000004242 Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf Mitigation For more information see the associated Schneider Electric CPCERT security advisory SEVD-2026-069-02 Improper Neutralization in Multiple Products - PDF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-02.pdf. Improper Neutralization in Multiple Products - SEVD-2026-069-02 CSAF Version: https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json. https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2026-069-02.json Relevant CWE: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N Acknowledgments Amir Zaltzman of Claroty Team82 reported this vulnerability to Schneider Electric Schneider Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-03-19 Date Revision Summary 2026-03-19 1 Initial Republication of Schneider Electric CPCERT SEVD-2026-069-02 Legal Notice and Terms of Use

Okta made a nightmare micromanager for your AI agents
Gouvernance & RégulationThe Register Securityil y a 12 jours

Where are you? What are you working on? Why are you doing that? Identity access and management platform Okta announced the general availability of its Okta for AI Agents, which will give customers the ability to do three things: locate agents, see what they’re doing, and shut them down if need be.…

Ransomware crims abused Cisco 0-day weeks before disclosure, says Amazon security boss
Gouvernance & RégulationThe Register Securityil y a 12 jours

Interlock's post-exploit toolkit exposed Ransomware criminals exploited CVE-2026-20131, a maximum-severity bug in Cisco Secure Firewall Management Center software, as a zero-day vulnerability more than a month before Cisco patched the hole, according to Amazon security boss CJ Moses.…

North Korea's 100,000-strong fake IT worker army rake in $500M a year for Kim Jong Un
Vulnérabilités & PatchesThe Register Securityil y a 12 jours

Researchers map full org chart of the scam from dodgy recruiters to helpful Western collaborators Researchers at IBM X‑Force and Flare Research have uncovered data that sheds light on how North Korea's fake IT worker schemes operate and infiltrate companies in order to funnel money back to the regime and steal sensitive information.…

SideWinder Espionage Campaign Expands Across Southeast Asia
Threat IntelligenceDark Readingil y a 12 jours

The suspected India-linked threat group targets governments, telecom, and critical infrastructure using spear-phishing, old vulnerabilities, and rapidly rotating infrastructure to maintain persistent access.

Britain's satellite-watching gap to be plugged with £17.5M eyeball in Cyprus
Gouvernance & RégulationThe Register Securityil y a 12 jours

No 1 Space Operations Squadron will get a persistent stare capability The Ministry of Defence (MoD) plans to spend £17.5 million on a remotely-operated satellite monitoring facility in Cyprus, partly to protect the UK's secure communications system Skynet.…

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 12 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2025-66376 Synacor Zimbra Collaboration Suite (ZCS) Cross-Site Scripting Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

CISA Adds One Known Exploited Vulnerability to Catalog
Gouvernance & RégulationCISA Advisoriesil y a 12 jours

CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation. CVE-2026-20963 Microsoft SharePoint Deserialization of Untrusted Data Vulnerability This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise. Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the KEV Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information. Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of KEV Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

CISA Urges Endpoint Management System Hardening After Cyberattack Against US Organization
Vulnérabilités & PatchesCISA Advisoriesil y a 12 jours

CISA is aware of malicious cyber activity targeting endpoint management systems of U.S. organizations based on the March 11, 2026 cyberattack against U.S.-based medical technology firm Stryker Corporation, which affected their Microsoft environment.1 To defend against similar malicious cyber activity, CISA urges organizations to harden endpoint management system configurations using the recommendations and resources provided in this alert. CISA is conducting enhanced coordination with federal partners, including the Federal Bureau of Investigation (FBI), to identify additional threats and determine mitigation actions. To defend against similar malicious activity that misuses legitimate endpoint management software, CISA urges organizations to implement Microsoft’s newly released best practices for securing Microsoft Intune; the principles of these recommendations can be applied to Intune and more broadly to other endpoint management software: Use principles of least privilege when designing administrative roles. Leverage Microsoft Intune’s role-based access control (RBAC) to assign the minimum permissions necessary to each role for completing day-to-day operations—permissions include what actions the role can take, and what users and devices it can apply that action to. Enforce phishing-resistant multi-factor authentication (MFA) and privileged access hygiene. Use Microsoft Entra ID capabilities (including Conditional Access, MFA, risk signals, and privileged access controls) to block unauthorized access to privileged actions in Microsoft Intune. Configure access policies to require Multi Admin Approval in Microsoft Intune. Set up policies that require a second administrative account’s approval to allow changes to sensitive or high-impact actions (such as device wiping), applications, scripts, RBAC, configurations, etc. Additionally, CISA recommends reviewing the following resources to strengthen defenses against similar malicious cyber activity: Microsoft resources: For recommendations on securing Microsoft Intune, see Best practices for securing Microsoft Intune. For guidance on implementing Multi Admin Approval in Microsoft Intune, see Use Access policies to implement Multi Admin Approval. For recommendations on configuring Microsoft Intune using zero trust principles, see Configure Microsoft Intune for increased security. For guidance on implementing Microsoft Intune RBAC policies, see Role-based access control (RBAC) with Microsoft Intune. For guidance on deploying Privileged Identity Management (PIM) across Microsoft Intune, Entra ID, and other Microsoft software, see Plan a Privileged Identity Management deployment. CISA resources: For guidance on implementing phishing-resistant multifactor authentication (MFA), see Implementing Phishing-Resistant MFA. Disclaimer The information in this report is being provided “as is” for informational purposes only. CISA does not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial entities, products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by CISA. Acknowledgements Microsoft and Stryker contributed to this alert. Notes 1 For updates from Stryker on the incident, see “Customer Updates: Stryker Network Disruption,” Stryker, last modified March 15, 2026, https://www.stryker.com/us/en/about/news/2026/a-message-to-our-customers-03-2026.html.

Japan to allow ‘proactive cyber-defense’ from October 1st
Gouvernance & RégulationThe Register Securityil y a 13 jours

In less polite places, this is called ‘hacking back’ or ‘offensive cyber-ops’ Japan’s government yesterday decided to allow its Self-Defense Force to conduct offensive cyber-operations, starting on October 1st.…

More Attackers Are Logging In, Not Breaking In
Malware & RansomwareDark Readingil y a 13 jours

Credential theft soared in the second half of 2025, thanks in part to the industrialization of infostealer malware and AI-enabled social engineering.